Previous
Resettable PTCs
Radial Leaded PTC
60R Series
Dimensions (Inches)
Average Time Current Curves
E
A
MARKING
1000
100
10
B
D
C
Note: Stand-offs only used for 60R010-60R090
Part Number
‘A’ (Max.)
‘B’ (Max.)
‘C’ (Typ.)
60R010
60R017
60R020
60R025
60R030
7.37 (0.29)
7.37 (0.29)
7.37 (0.29)
7.37 (0.29)
7.37 (0.29)
12.7 (0.50)
12.7 (0.50)
12.19 (0.48)
12.7 (0.50)
12.95 (0.51)
5.08 (0.20)
5.08 (0.20)
5.08 (0.20)
5.08 (0.20)
5.08 (0.20)
1
60R040
60R050
60R065
60R075
60R090
7.62 (0.30)
7.62 (0.30)
9.65 (0.38)
10.41 (0.41)
11.68 (0.46)
13.46 (0.53)
13.72 (0.54)
14.48 (0.57)
15.24 (0.60)
15.75 (0.62)
5.08 (0.20)
5.08 (0.20)
5.08 (0.20)
5.08 (0.20)
5.08 (0.20)
60R110
60R135
60R160
60R185
60R250
12.95 (0.51)
14.48 (0.57)
16.26 (0.64)
17.78 (0.70)
21.34 (0.84)
18.0 (0.71)
19.56 (0.77)
21.34 (0.84)
22.86 (0.90)
26.42 (1.04)
5.08 (0.20)
5.08 (0.20)
5.08 (0.20)
5.08 (0.20)
10.16 (0.40)
6
0.1
60R300
60R375
24.89 (0.98)
28.45 (1.12)
29.97 (1.18)
33.53 (1.32)
10.16 (0.40)
10.16 (0.40)
0.01
Dimension ‘D’ is 0.30" Minimum
Dimension ‘E’ is 0.12" Maximum
0.05 0.1
1
10
CURRENT IN AMPERES
100
500
ORDERING INFORMATION:
Maximum Time
To Trip
Resistance
Part
Number
Ihold
(A)
Itrip
(A)
Vmax
(Vdc)
Imax
(A)
Pd max.
(W)
Current
(A)
Time
(Sec)
RIL
(W)
RAT
(W)
60R010
60R017
60R020
60R025
60R030
0.10
0.17
0.20
0.25
0.30
0.20
0.34
0.40
0.50
0.60
60
60
60
60
60
40
40
40
40
40
0.38
0.48
0.41
0.45
0.49
0.50
0.85
1.00
1.25
1.50
4.0
3.0
2.2
2.5
3.0
2.50
3.30
1.83
1.25
0.88
7.50
8.00
4.40
3.00
2.10
60R040
60R050
60R065
60R075
60R090
0.40
0.50
0.65
0.75
0.90
0.80
1.00
1.30
1.50
1.80
60
60
60
60
60
40
40
40
40
40
0.56
0.77
0.88
0.92
0.99
2.00
2.50
3.25
3.75
4.50
3.8
4.0
5.3
6.3
7.2
0.55
0.50
0.31
0.25
0.20
1.29
1.17
0.72
0.60
0.47
60R110
60R135
60R160
60R185
60R250
1.10
1.35
1.60
1.85
2.50
2.20
2.70
3.20
3.70
5.00
60
60
60
60
60
40
40
40
40
40
1.50
1.70
1.90
2.10
2.50
5.50
6.75
8.2
9.6
11.4
12.6
15.6
0.15
0.12
0.09
0.08
0.05
0.38
0.30
0.22
0.19
0.13
8.00
9.25
12.50
60R300
60R375
3.00
3.75
6.00
7.50
60
60
40
40
2.80
3.20
15.00
18.75
19.8
24.0
0.04
0.03
0.10
0.08
I
I
=
=
=
=
=
=
=
Hold Current: maximum current device will sustain for 4 hours without tripping in 20°C still air.
Trip Current: minimum current at which the device will trip in 20°C still air.
Maximum voltage device can withstand without damage at rated current (Imax)
Maximum fault current device can withstand without damage at rated voltage (Vmax)
Power dissipated from device when in the tripped state at 20°C still air.
Minimum resistance of device in initial (un-soldered) state.
hold
trip
max
V
I
max
P
d
IL
AT
R
R
Maximum resistance of device at 20°C measured one hour after tripping.
CAUTION: Operation beyond the specified ratings may result in damage and possible arcing and flame.
255
www. littelfuse. com