5秒后页面跳转
5EFM4C PDF预览

5EFM4C

更新时间: 2024-01-15 17:51:41
品牌 Logo 应用领域
泰科 - TE 过滤器连接器医疗
页数 文件大小 规格书
8页 304K
描述
Power Entry Module with Optional RFI Power Line Filters for General and Medical Applications

5EFM4C 技术参数

是否无铅: 不含铅是否Rohs认证: 符合
生命周期:ActiveReach Compliance Code:compliant
ECCN代码:EAR99HTS代码:8536.69.40.30
风险等级:2.31连接器类型:MAINS POWER CONNECTOR
联系完成配合:NOT SPECIFIED触点性别:MALE
触点材料:NOT SPECIFIED耦合类型:SNAP
DIN 符合性:NOIEC 符合性:NO
MIL 符合性:NO电源连接器额定值:5/4A, 120/250VAC
安装类型:PANEL选件:GENERAL PURPOSE
触点总数:3Base Number Matches:1

5EFM4C 数据手册

 浏览型号5EFM4C的Datasheet PDF文件第1页浏览型号5EFM4C的Datasheet PDF文件第3页浏览型号5EFM4C的Datasheet PDF文件第4页浏览型号5EFM4C的Datasheet PDF文件第5页浏览型号5EFM4C的Datasheet PDF文件第6页浏览型号5EFM4C的Datasheet PDF文件第7页 
CORCOM Product Guide  
Power Entry Module with Optional RFI Power Line Filters for General and  
Medical Applications (Continued)  
M Series  
Removing the Fuse Holder  
Fuse Options  
European Fusing Arrangement**  
1. Insert a pocket screwdriver at point “X” as shown.  
"X"  
A
A
Section A-A  
North American Fusing Arrangement**  
Gently lift UP until the entire door lifts up approximately  
1/4" (minimum).  
Lift Up  
2. Once lifted, the door will pivot on it’s hinges and  
expose the fuse holder.  
**Install fuses on one side only. Do Not install both AG and Metric fuses at  
the same time.  
Voltage Selection  
To change selected voltage: open cover, using small  
blade screwdriver or similar tool; set aside cover/fuse  
block assembly; pull voltage selector card straight out of  
housing, using indicator pin; orient selector card so that  
desired voltage is readable at the bottom; orient indicator  
pin to point up when desired voltage is readable at bottom  
(note that when indicator pin is fixed, successive voltages  
are selected by rotating the card 90° clockwise); insert  
voltage selector card into housing, printed side of card  
facing forward toward IEC connector and edge containing  
the desired voltage first; replace cover, and verify that  
indicator pin shows the desired voltage.  
3. When the fuse holder is installed in the single fuse  
position, apply the screwdriver as shown and gently  
pry up. Use screwdriver as shown, do not use fingers.  
Voltage Selector Card Orientation  
When the fuse holder is installed in the dual fuse  
position, it will normally release as soon as the  
door is opened.  
4
2
3
2
0
1
0
0
1
2
120V  
100V  
1
0
0
2
3
0
0
2
4
230V  
240V  
125  
Catalog 1654001  
Revised 05-07  
Dimensions are in inches and  
millimeters unless otherwise  
specified. Values in italics  
are metric equivalents.  
Dimensions are shown for  
reference purposes only.  
Specifications subject  
to change.  
USA Cust. Svc.: 1-800-468-2023  
CORCOM Prods: 1-847-680-7400  
www.corcom.com  
www.tycoelectronics.com  
Germany:  
49-89-6089-0  

与5EFM4C相关器件

型号 品牌 描述 获取价格 数据表
5EFM4S TE Power Entry Module with Optional RFI Power Line Filters for General and Medical Applicatio

获取价格

5EFM4SC TE Power Entry Module with Optional RFI Power Line Filters for General and Medical Applicatio

获取价格

5EHM1 TE Power Entry Module with Optional RFI Power Line Filters for General and Medical Applicatio

获取价格

5EHM1S TE Power Entry Module with Optional RFI Power Line Filters for General and Medical Applicatio

获取价格

5EHM4 TE Power Entry Module with Optional RFI Power Line Filters for General and Medical Applicatio

获取价格

5EHM4S TE Power Entry Module with Optional RFI Power Line Filters for General and Medical Applicatio

获取价格