absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
CC
Input voltage, V : Control inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
I
I/O ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
Operating free-air temperature range, T : SN54ALS652 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –55°C to 125°C
A
SN74ALS651A, SN74ALS652A . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range, T
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
stg
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN74ALS651A
MIN NOM MAX
UNIT
V
V
V
Supply voltage
4.5
2
5
5.5
V
V
CC
High-level input voltage
Low-level input voltage
High-level output current
IH
0.8
–15
24
V
IL
I
I
f
t
mA
OH
Low-level output current
Clock frequency
mA
MHz
ns
OL
clock
w
‡
48
0
12.5
12.5
10
40
CLKBA or CLKAB high
CLKBA or CLKAB low
A or B
Pulse duration
t
t
Setup time before CLKAB↑ or CLKBA↑
Hold time after CLKAB↑ or CLKBA↑
Operating free-air temperature
ns
ns
°C
su
A or B
0
h
T
A
0
70
‡
Applies only to the SN74ALS651A-1 and only if V
CC
is maintained between 4.75 V and 5.25 V
recommended operating conditions
SN54ALS652
MIN NOM MAX
SN74ALS652A
UNIT
MIN NOM
MAX
V
V
V
Supply voltage
4.5
2
5
5.5
4.5
2
5
5.5
V
V
CC
High-level input voltage
Low-level input voltage
High-level output current
IH
0.7
–12
12
0.8
–15
24
V
IL
I
I
f
t
mA
OH
Low-level output current
Clock frequency
mA
MHz
ns
OL
clock
w
‡
48
0
14.5
14.5
15
35
0
12.5
12.5
10
40
CLKBA or CLKAB high
CLKBA or CLKAB low
A or B
Pulse duration
t
t
Setup time before CLKAB↑ or CLKBA↑
Hold time after CLKAB↑ or CLKBA↑
Operating free-air temperature
ns
ns
°C
su
A or B
5
0
h
T
A
–55
125
0
70
‡
Applies only to the SN74ALS652A-1 and only if V
CC
is maintained between 4.75 V and 5.25 V
7