IMX35 Series Data Sheet
35 Watt Quad-Output DC-DC Converters
®
Model Selection
Table 1: Model Selection
Output 1
Output 2
Output 3
Output 4
Input voltage
Vi min to Vi max
[V]
Efficiency 1
Model
Opt.
Vonom
Ionom
Vonom
Ionom
Vonom
Ionom
Vonom
Ionom
η
η
typ
min
[V]
[A]
[V]
[A]
[V]
[A]
[V]
[A]
[%]
[%]
5
5
5
5
1.35
1.4
1.4
1.4
5
5
5
5
1.35
1.4
1.4
1.4
5
5
5
5
1.35
1.4
1.4
1.4
5
5
5
5
1.35
1.4
1.4
1.4
9 to 36
82.5
86
87
86
86
20IMX35D05D05-8
40IMX35D05D05-8
70IMX35D05D05-8
110IMX35D05D05-8
i
Z
G
18 to 75
82
40 to 121
60 to 1502
83
82
12
12
12
12
0.65
0.7
0.7
0.7
12
12
12
12
0.65
0.7
0.7
0.7
12
12
12
12
0.65
0.7
0.7
0.7
12
12
12
12
0.65
0.7
0.7
0.7
9 to 36
18 to 75
83.7
83.7
85
86
88
88
88
20IMX35D12D12-8
40IMX35D12D12-8
70IMX35D12D12-8
110IMX35D12D12-8
40 to 121
60 to 1502
84
15
15
15
15
0.55
0.6
0.6
0.6
15
15
15
15
0.55
0.6
0.6
0.6
15
15
15
15
0.55
0.6
0.6
0.6
15
15
15
15
0.55
0.6
0.6
0.6
9 to 36
18 to 75
85
83.6
84.5
83
88
89
88
88
20IMX35D15D15-8
40IMX35D15D15-8
70IMX35D15D15-8
110IMX35D15D15-8
40 to 121
60 to 1502
5
5
5
5
1.35
1.4
1.4
1.4
12
12
12
12
0.65
0.7
0.7
0.7
12
12
12
12
0.65
0.7
0.7
0.7
5
5
5
5
1.35
1.4
1.4
1.4
9 to 36
18 to 75
84
84
88
89
88
88
20IMX35D05D12-8
40IMX35D05D12-8
70IMX35D05D12-8
110IMX35D05D12-8
40 to 121
84
60 to 1502
83.6
5
5
5
5
1.35
1.4
1.4
1.4
15
15
15
15
0.55
0.6
0.6
0.6
15
15
15
15
0.55
0.6
0.6
0.6
5
5
5
5
1.35
1.4
1.4
1.4
9 to 36
18 to 75
83.5
83.5
84
88
89
88
88
20IMX35D05D15-8
40IMX35D05D15-8
70IMX35D05D15-8
110IMX35D05D15-8
40 to 121
60 to 1502
84
1
2
Efficiency at TA = 25 °C, Vo nom, Io nom
154 V for 2 s.
Part Number Description
Input voltage range Vi
40 IMX35 D05 D05 -8 i Z G
9 to 36 VDC ........................................... 20
18 to 75 VDC ........................................... 40
40 to 121 VDC ........................................... 70
60 to 150 VDC ......................................... 110
Series ....................................................................... IMX35
Outputs 1 and 4 (1st power train)............... D05, D12, D15
Outputs 2 and 3 (2nd power train) .............. D05, D12, D15
Operating ambient temperature range
TA = –40 to 85 °C ...................................... -8
Options:
Inhibit ........................................................... -i
Open frame ................................................. Z
RoHS compliant for all six substances ........ G1
1
G is always placed at the end of the part number.
Preferred for new designs
Product Marking
Converters without option Z are marked with type designation,
input and output voltages and currents, applicable safety
approval and recognition marks, company logo, production
date, and serial no.
BCD20009-G Rev AC, 06-May-2013
Page 2 of 15