4.0SMDJ Series
Maximum
Reverse
Stand-Off
Voltage
Breakdown Breakdown
Peak
Pulse
Current
Reverse
Leakage
@VRMW
Test
Current
Clamping
Voltage
@IPP
Type Number
Marking
Voltage
Voltage
Min. @IT
Max. @ IT
(Uni)
(Bi)
(Uni)
(Bi)
IGT
IGV
IGX
IGZ
IHE
IHG
IHK
IHM
IHP
IHR
VRMW(V)
78.0
VBR MIN(V)
86.70
VBR MAX(V)
95.80
IT (mA)
VC(V)
126.0
137.0
146.0
162.0
177.0
193.0
209.0
243.0
259.0
275.0
IPP(A)
40.5
37.2
34.9
31.5
28.8
26.4
24.4
21.0
19.7
18.5
IR(uA)
4.0SMDJ78A 4.0SMDJ78CA
4.0SMDJ85A 4.0SMDJ85CA
4.0SMDJ90A 4.0SMDJ90CA
4.0SMDJ100A 4.0SMDJ100CA
4.0SMDJ110A 4.0SMDJ110CA
4.0SMDJ120A 4.0SMDJ120CA
4.0SMDJ130A 4.0SMDJ130CA
4.0SMDJ150A 4.0SMDJ150CA
4.0SMDJ160A 4.0SMDJ160CA
4.0SMDJ170A 4.0SMDJ170CA
HGT
HGV
HGX
HGZ
HHE
HHG
HHK
HHM
HHP
HHR
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
85.0
94.40
104.00
111.00
123.00
135.00
147.00
159.00
185.00
197.00
209.00
90.0
100.00
111.00
122.00
133.00
144.00
167.00
178.00
189.00
100.0
110.0
120.0
130.0
150.0
160.0
170.0
※ For Bi-directional type having VRWM of 10 Volts and less, the IR limit is double.
※ For parts without A, the VBR is ± 10% and VC is 5% higher than with A parts.
I-V Curve Characteristics
Bi-directional
Uni-directional
PPPM Peak Pulse Power Dissipation - Max power dissipation
VRWM Reverse Stand-off Voltage - Maximum voltage that can be applied to TVS without operation
VBR
VC
IR
Breakdown Voltage – Maximum voltage that flows though the TVS at a specified current (IT)
Clamping Voltage – Peak voltage measured across the TVS at a specified IPPM (peak impulse current)
Reverse Leakage Current – Current measured at VR
VF
Forward Voltage Drop for Uni-directional
Rev. 2.0, 10-Nov.-16
WWW.SEMITECH.CN