3000W Transient Voltage Suppressor
Electrical Characteristics (TA=25°C unless otherwise noted)
Working
Peak
Reverse
Voltage
VRWM (V)
Maximum
Reverse
Leakage
at VRWM
IR (uA)
Maximum
Reverse
Surge
Maximum
Clamping
Breakdown Voltage
VBR (V) @ IT
Marking Code
Voltage
Part No.
Current
at IPP
Vc(V)
IT(mA)
UNI
BI
MIN.(V)
MAX.(V)
IPP(A)
3KP58(C)A-HF
3KP60(C)A-HF
3KP64(C)A-HF
3KP70(C)A-HF
3KP58A
3KP60A
3KP64A
3KP70A
3KP58CA
3KP60CA
3KP64CA
3KP70CA
64.4
66.7
71.1
77.8
71.2
73.7
78.6
86.0
5
5
5
5
2
2
2
2
58.0
60.0
64.0
70.0
32.05
30.99
29.13
26.55
93.6
96.8
103.0
113.0
3KP75(C)A-HF
3KP78(C)A-HF
3KP80(C)A-HF
3KP85(C)A-HF
3KP75A
3KP78A
3KP80A
3KP85A
3KP75CA
3KP78CA
3KP80CA
3KP85CA
83.3
86.7
88.8
94.4
92.1
95.8
5
5
5
5
2
2
2
2
75.0
78.0
80.0
85.0
24.79
23.81
23.15
21.9
121.0
126.0
137.0
137.0
97.6
104.0
3KP90(C)A-HF
3KP100(C)A-HF
3KP110(C)A-HF
3KP120(C)A-HF
3KP90A
3KP90CA
3KP100CA
3KP110CA
3KP120CA
100
111
122
133
111
123
135
147
5
5
5
5
2
2
2
2
90
20.55
18.52
16.95
15.54
146
162
177
193
3KP100A
3KP110A
3KP120A
100
110
120
3KP130(C)A-HF
3KP140(C)A-HF
3KP150(C)A-HF
3KP160(C)A-HF
3KP130A
3KP140A
3KP150A
3KP160A
3KP130CA
3KP140CA
3KP150CA
3KP160CA
144
155
167
178
159
171
185
197
5
5
5
5
2
2
2
2
130
140
150
160
14.35
13.23
12.35
11.58
209
227
243
259
3KP170(C)A-HF
3KP180(C)A-HF
3KP190(C)A-HF
3KP200(C)A-HF
3KP170A
3KP180A
3KP190A
3KP200A
3KP170CA
3KP180CA
3KP190CA
3KP200CA
189
200
211
224
209
220
232
247
5
5
5
5
2
2
2
2
170
180
190
200
10.91
10.29
9.75
275
292
308
324
9.26
3KP210(C)A-HF
3KP220(C)A-HF
3KP250(C)A-HF
3KP300(C)A-HF
3KP210A
3KP220A
3KP250A
3KP300A
3KP210CA
3KP220CA
3KP250CA
3KP300CA
233
246
279
335
258
272
309
371
5
5
5
5
2
2
2
2
210
220
250
300
8.58
8.43
7.41
6.17
350
356
405
486
3KP350(C)A-HF
3KP400(C)A-HF
3KP440(C)A-HF
3KP350A
3KP400A
3KP440A
3KP350CA
3KP400CA
3KP440CA
391
447
492
432
494
543
5
5
5
2
2
2
350
400
440
5.29
4.63
4.21
567
648
713
NOTES:
1. Suffix 'A ' denotes 5% tolerance device.
2. Add suffix 'C 'or ' CA ' after part number to specify Bi-directional devices.
3. For Bi-Directional devices having VR of 10 volts and under, the IR limit is double.
Company reserves the right to improve product design , functions and reliability without notice.
REV:A
Page 4
QW-JTV13