CPS Series  
Cable Pull Safety Switch  
FEATURES  
Direct opening action  
of NC  
(normally closed) contacts  
2CPS: 2NO/2NC, 1NO/3NC or 4NC  
contact configurations  
1CPS: 1NO/1NC, 2NO/2NC, 1NO/3NC or  
4NC contact configurations  
Typical cable span of 76 m (250 ft) in an  
environment with a temperature change  
of ±17 °C (±30 °F). Longer spans are  
possible depending upon temperature  
change and installation  
BG  
(Applied for)  
(ref. note on page 6 for more details or  
Application note - Effect of Temperature  
on Cable Pull Switch Operation)  
Choice of three actuator configurations  
(2CPS)  
Removable contact block version  
available (2CPS)  
Large wiring cavity with straight-  
through wiring  
CPS Series Cable Pull Safety Switches provide a readily accessible emergency stop  
signal. This is a cost-effective means compared to using multiple emergency stop  
push-buttons. (Cable Pull Safety Switches are not, however, to be used as a means  
of personnel safeguarding. They may be used to prevent further injury or damage to  
equipment when used for emergency stop signaling.)  
The CPS Series Cable Pull Safety switch is designed to provide emergency stop  
protection for exposed conveyor and assembly lines. The internal mechanism  
latches on both slackened cable (push) and pulled cable. This capability also en-  
hances productivity by eliminating nuisance stops due to variations in temperature,  
stretch of cable over time, and other application variables.  
24 Vdc or 120 Vac bright, multicluster  
LED status indicator light available on  
2CPS. Single high intensity LED on 1CPS  
Gold-plated contacts are standard on  
2CPS, available on 1CPS  
The 1CPS is intended for use in applications where the cable span is 76 m (250 ft)  
or shorter. It is an economical solution for shorter runs or zone protection typical to  
automated systems. The 2CPS series is intended for use in very long cable runs of  
152 m (500 ft) or shorter, such as long conveyor lines found in warehouses.  
Die-cast zinc housing  
Optional hardware packs available  
A line in the midpoint of the cable tension window indicates proper cable tension,  
providing easy set-up. The direct opening switch contacts are held closed when the  
actuating cable is under proper tension and the reset knob is set to RUN. When the  
actuating cable is pulled, slackened or broken, a cam positively opens the NC (Nor-  
mally Closed) switch contacts. The snap action, trip operation causes the switch  
contacts to change state and mechanically latch almost simultaneously when the  
cable is pulled, slackened or broken. The NC switch contacts remain open until the  
CPS is reset by properly tensioning the cable and manually rotating the reset knob.  
TYPICAL APPLICATIONS  
Long conveyor systems found in  
warehouses and distribution centers  
Conveyor systems having a high amount  
of vibration  
Conveyor systems that experience wide  
temperature swings  
Long conveyor systems where easy  
through wiring, or highly visible trip  
status is required  
Hose down conditions  
Packaging equipment  
Assembly lines  
When the direct opening switch contacts open, the auxiliary contacts also actuate  
(open contacts close and closed contacts open). The auxiliary contacts are electri-  
cally isolated from the direct opening switch contacts. These NO (Normally Open)  
contacts may be used for monitoring or signaling.  
The CPS complies with: Low Voltage Directive 73/23/EEC, as amended by directive  
93/68/EEC; Machinery Directive 98/37/EEC only as the directives relate to the  
components being used in a safety function; IEC/EN 60947-1; IEC/EN 60947-5-1;  
IEC/EN 60947-5-5.  
!
WARNING  
MISUSE OF DOCUMENTATION  
The information presented in this product sheet (or catalogue) is for reference only. DO NOT USE this document as system  
installation information.  
Complete installation, operation and maintenance information is provided in the instructions supplied with each product.  
Failure to comply with these instructions could result in death or serious injury.  
Safety Products for Machine Safeguarding •  
1
© Honeywell International Inc. - April 2003  

与2CPSA2D2B相关器件

型号 品牌 获取价格 描述 数据表
2CPSA2D3 HONEYWELL

获取价格

Snap Acting/Limit Switch
2CPSA2D3B HONEYWELL

获取价格

Snap Acting/Limit Switch, 4PST, Momentary, 2.8A, 24VDC, Connector Terminal, Panel Mount
2CPSB1A1B HONEYWELL

获取价格

Snap Acting/Limit Switch, 4PST, Momentary, 2.8A, 24VDC, Panel Mount
2CPSB1A2A HONEYWELL

获取价格

Snap Acting/Limit Switch, 4PST, Momentary, 2.8A, 24VDC, Panel Mount
2CPSB1A4A HONEYWELL

获取价格

Snap Acting/Limit Switch, 4PST, Momentary, 2.8A, 24VDC, Screw Terminal, Panel Mount
2CPSB1A4B HONEYWELL

获取价格

Snap Acting/Limit Switch, 4PST, Momentary, 2.8A, 24VDC, Screw Terminal, Panel Mount
2CPSB1A5A HONEYWELL

获取价格

Snap Acting/Limit Switch, 4PST, Momentary, 2.8A, 24VDC, Screw Terminal, Panel Mount
2CPSB1A5B HONEYWELL

获取价格

Snap Acting/Limit Switch, 4PST, Momentary, 2.8A, 24VDC, Screw Terminal, Panel Mount
2CPSB1A6A HONEYWELL

获取价格

Snap Acting/Limit Switch, 4PST, Momentary, 2.8A, 24VDC, Screw Terminal, Panel Mount
2CPSB1A6B HONEYWELL

获取价格

Snap Acting/Limit Switch, 4PST, Momentary, 2.8A, 24VDC, Screw Terminal, Panel Mount