2A-YJD&2B-YJD Series
General Specifications
Parameter
Conditions
Min.
1500
1650
1000
---
Typ.
---
Max.
---
Unit.
VDC
VDC
MΩ
Isolation Voltage Rated
Isolation Voltage Test
Isolation Resistance
Isolation Capacitance
Switching Frequency
MTBF
60 Seconds
Flash Tested for 1 Second
500VDC
---
---
---
---
100KHz,1V
250
300
---
420
---
pF
---
KHz
MIL-HDBK-217F @ 25℃, Ground Benign
1000
---
K Hours
Notes :
1. Specifications typical at Ta=+25℃, resistive load, nominal input voltage, rated output current unless otherwise noted.
2. Transient recovery time is measured to within 1%error band for a step change in output load of 75% to 100%.
3. Ripple & Noise measurement bandwidth is 0-20 MHz.
4. These power converters require a minimum output loading to maintain specified regulation.
5. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed.
6. All DC/DC converters should be externally fused on the front end for protection.
7. Other input and output voltage may be available, please contact factory.
8. Specifications subject to change without notice
Block Diagram
Single Output
Dual Output
Input Voltage Transient Rating
http://www.microdc.cn Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 3 of 6