GENERAL DATA — 500 mW DO-35 GLASS
*ELECTRICAL CHARACTERISTICS (T = 30°C unless otherwise noted.) (V = 1.5 Volts Max @ I = 100 mAdc for all types.)
L
F
F
Nominal
Zener Voltage
Max DC
Zener
Max Zener Impedance (Note 3)
Max Reverse Leakage Current
Motorola
Type
Number
(Note 1)
Test
Current
V
@ I
Volts
Current
Z
ZT
@
I
V
R
Volts
Z
@ I
Ohms
Z
ZK
@ I =
ZK
I
I
R
ZT
ZT
ZT
ZM
µA
Ohms 0.25 mA
mA
(Note 4)
(Note 2)
1N5985B
1N5987B
1N5988B
1N5989B
2.4
3
3.3
3.6
5
5
5
5
100
95
95
1800
2000
2200
2300
100
50
25
1
1
1
1
208
167
152
139
90
15
1N5990B
1N5991B
1N5992B
1N5993B
1N5994B
3.9
4.3
4.7
5.1
5.6
5
5
5
5
5
90
88
70
50
25
2400
2500
2200
2050
1800
10
5
3
2
2
1
1
1.5
2
128
116
106
98
3
89
1N5995B
1N5996B
1N5997B
1N5998B
1N5999B
6.2
6.8
7.5
8.2
9.1
5
5
5
5
5
10
8
7
7
10
1300
750
600
600
600
1
1
0.5
0.5
0.1
4
5.2
6
6.5
7
81
74
67
61
55
1N6000B
1N6002B
1N6003B
1N6004B
1N6006B
10
12
13
15
18
5
5
5
5
5
15
22
25
32
42
600
600
600
600
600
0.1
0.1
0.1
0.1
0.1
8
50
42
38
33
28
9.1
9.9
11
14
*Indicates JEDEC Registered Data
NOTE 1. TOLERANCE AND VOLTAGE DESIGNATION
NOTE 3.
Tolerance designation — Device tolerances of ±5% are indicated by a “B” suffix, ±2% by a
“C” suffix, ±1% by a “D” suffix.
Z
andZ aremeasuredbydividingtheacvoltagedropacrossthedevicebytheaccurrent
ZK
ZT
applied. The specified limits are for I (ac) = 0.1 I (dc) with the ac frequency = 1.0 kHz.
Z
Z
NOTE 2.
NOTE 4.
This data was calculated using nominal voltages. The maximum current handling capability
on a worst case basis is limited by the actual zener voltage at the operating point and the pow-
er derating curve.
Nominal Zener Voltage (V ) is measured with the device junction in thermal equilibrium atthe
Z
lead temperature of 30°C ±1°C and 3/8″ lead length.
Motorola TVS/Zener Device Data
500 mW DO-35 Glass Data Sheet
6-2