5秒后页面跳转
1800-XC6DT2-PRIME PDF预览

1800-XC6DT2-PRIME

更新时间: 2022-02-26 15:00:41
品牌 Logo 应用领域
MTU /
页数 文件大小 规格书
4页 411K
描述
DIESEL GENERATOR SET

1800-XC6DT2-PRIME 数据手册

 浏览型号1800-XC6DT2-PRIME的Datasheet PDF文件第1页浏览型号1800-XC6DT2-PRIME的Datasheet PDF文件第2页浏览型号1800-XC6DT2-PRIME的Datasheet PDF文件第3页 
/ // /  
4
1800-XC6DT2  
WEIGHTS AND DIMENSIONS  
Drawing above for illustration purposes only, based on standard open power 480 volt generator set. Lengths may vary with other voltages. Do not use for installation design. See website  
for unit specic template drawings.  
System  
Dimensions (LxWxH)  
Weight (less tank)  
OPU  
6,550 x 2,560 x 2,860 mm (258 x 100.6 x 112.5 in)  
16,477 kg (36,326 lb)  
Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specic generator set.  
SOUND DATA  
Unit Type  
Prime Full Load  
Level 0: Open Power Unit dB(A)  
94.7  
Sound data is provided at 7 m (23 ft). Generator set tested in accordance with ISO 8528-10 and with innite exhaust.  
EMISSIONS DATA  
RATING DEFINITIONS AND CONDITIONS  
//ꢀ  
NOx + NMHC  
5.27  
CO  
0.6  
PM  
0.06  
Prime power ratings apply to installations where utility power  
is unavailable or unreliable. At varying load, the number of  
generator set operating hours is unlimited. A 10% overload  
capacity is available for one hour in twelve. Ratings are in  
accordance with ISO 8528-1, ISO 3046-1, BS 5514, AS 2789,  
and DIN 6271.  
Deration Factor:  
Altitude: Consult your local MTU Onsite Energy Power  
Generation Distributor for altitude derations.  
All units are in g/hp-hr and at 100% load.  
Emission levels of the engine may vary as a function of ambient  
temperature, barometric pressure, humidity, fuel type and  
quality, installation parameters, measuring instrumentation,  
etc. The data provided are laboratory results from one  
engine representing this rating. The data was obtained  
under controlled environmental conditions with calibrated  
instrumentation traceable to the United States National Bureau  
of Standards and in compliance with US EPA regulations found  
within 40 CFR Part 89. The weighted cycle value (not shown)  
from each engine is guaranteed to be below the US EPA  
Standards at the US EPA dened conditions.  
//ꢀ  
Temperature: Consult your local MTU Onsite Energy Power  
Generation Distributor for temperature derations.  
Materials and specications subject to change without notice.  
C/F = Consult Factory/MTU Onsite Energy Distributor  
MTU Onsite Energy  
A Rolls-Royce Power Systems Brand  
www.mtuonsiteenergy.com  

与1800-XC6DT2-PRIME相关器件

型号 品牌 描述 获取价格 数据表
180-1 GILWAY Unbased Lens-End Lamps

获取价格

180-1.000MHZ-BC FOX HCMOS/TTL Output Clock Oscillator, 1MHz Nom, DIP-14/4

获取价格

180-10 JST Ring tongue terminal (R-type, Non-insulated)

获取价格

180-10%-FA10-20PPM-AMMOPACK VISHAY Fixed Resistor, Wire Wound, 10W, 180ohm, 700V, 10% +/-Tol, -20,20ppm/Cel,

获取价格

180-10%-FA1A-20PPM-TANDR VISHAY Fixed Resistor, Wire Wound, 1W, 180ohm, 44V, 10% +/-Tol, -20,20ppm/Cel,

获取价格

180-10%-FA3/4-20PPM-TANDR VISHAY Fixed Resistor, Wire Wound, 0.75W, 180ohm, 32V, 10% +/-Tol, -20,20ppm/Cel,

获取价格