Modular Signal Connectors – PLUSCON circular
M23 – RC Series
Cable connectors and cable connecting receptacles,
straight, shielded
Coding groove
Please note: torque for screw termination
• max. 0.1 Nm for screw contacts with
mating dia. 1 mm
• max. 0.2 Nm for screw contacts with
mating dia. 2 mm
• Push the adapter (1), the union nut (2) and the sealing • Strip the litz wires by 3.5 mm, twist (and tin plate).
element (4) with the gasket (3) onto the cable.
• Strip the external sheath by 23 mm.
• Detail A: Push back the braided screen such that it
stands out at 90°. With a rotating motion, push the
shielded sleeve (5A) over the foil or cotton braiding
and under the braided screen. Cut the braided screen
• Solder, crimp or screw the litz wires to the contacts.
• Insert the spacer sleeve (6).
• Guide the insert (7) and spacer sleeve (6) into the
insert sleeve (8), taking care that the desired coding
groove of the insert (7) is introduced into the coding
bar.
flush with the external diameter of the shielded sleeve • Press in the cable with the shield and sealing unit.
(5A).
• Screw the adapter (1) as tight as possible.
• Trim the foil, wadding and inner insulation.
Installation dimensions
Cable connecting receptacle for wall mounting
Ø2,7
M2,5
Flat gasket
Axial O-ring
Radial O-ring
RC-0000000B2FZ
(front mounting)
RC-0000000C0FZ
(rear mounting)
RC-0000000Q0FZ
(rear mounting)
Cable connectors and cable connecting receptacles with plastic cap,
straight, shielded
Coding groove
Please note: torque for screw termination
• max. 0.1 Nm for screw contacts with
mating dia. 1 mm
• max. 0.2 Nm for screw contacts with
mating dia. 2 mm
• Push the adapter (1), the union nut (2) and the seal-
ing element (4) with the gasket (3) onto the cable.
• Strip the external sheath by 23 mm.
• Push back the braided screen such that it stands out
at 90° and cut it flush with the outer diameter of the
shield disc (5).
• Trim the foil, wadding and inner insulation.
• Strip the litz wires by 3.5 mm, twist (and tin plate).
• Solder, crimp or screw the litz wires to the contacts.
• Insert the spacer sleeve (6).
• Guide the insert (7) and spacer sleeve (6) into the
insert sleeve (8), taking care that the desired coding
groove of the insert (7) is introduced into the coding
bar.
• Press in the cable with the shield and sealing unit.
• Screw the adapter (1) as tight as possible.
Attention: The required torque must not increase by
more than 10 Nm during this process, as this can
effect the free movement of the union nut.
PHOENIX CONTACT
4