140SC...-PCB / 420SC...-PCB Series
Signal conditioned precision pressure transducers
PERFORMANCE CHARACTERISTICS
4 - 20 mA output version (unless otherwise noted VS = 15 V, RL = 100 Ω, tamb = 25°C)
Characteristics
Operating pressure
Min.
Typ.
Max.
Unit
differential devices4
420SC01D-PCB
420SC05D-PCB
420SC15D-PCB
420SC30D-PCB
420SC100D-PCB
420SC150D-PCB
0
0
0
0
0
0
1
5
15
30
100
150
psid(g)
absolute devices5
420SC15A-PCB
420SC30A-PCB
420SC100A-PCB
0
0
0
15
30
100
psia
psid
pressure/vacuum devices4
423SC01D-PCB
423SC03D-PCB
423SC05D-PCB
423SC15D-PCB
-1
-2.5
-5
1
2.5
5
-15
15
Zero pressure offset
420SC...-PCB
423SC...-PCB
3.9
11.9
4.0
12.0
4.1
12.1
Full scale span6
420SC...-PCB
423SC...-PCB
15.8
7.9
16.0
8.0
16.2
8.1
mA
Full scale output
20.0
4.0
Output at lowest specified pressure
Non-linearity and hysteresis (BSL)7
423SC...-PCB
±0.1
±0.5
Thermal effects8
Combined offset and span
(0 to 70°C)
all 1 psi devices
all others
±1.5
±0.5
±2.0
±3.0
±1.5
%FSO
(-40 to 0°C, 70 to 100°C)
Repeatability
Long term stability9
±0.1
±0.1
±0.04
0.1
Output noise
Response time (10 to 90%)
Power supply rejection rate
ms
Offset
Span
0.05
0.03
%FSO/V
Specification notes:
1.
The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the
load limitation diagram.
2.
3.
Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
The output signal of all 141SC...-PCB devices is proportional to the vacuum applied to port B, relative to port A, e. g. the output
signal increases when pressure is applied to port A relative to port B.
4.
The output signal of all 142SC...D-PCB and 143SC...D-PCB devices is proportional to the pressure applied to port B, relative to
port A, e.g. the output signal increases when vacuum is applied to port A relative to port B.
The output signal of all 142SC...A-PCB is proportional to the pressure applied to port A.
Full scale span is the algebraic difference between the positive full scale output and the zero pressure offset.
Non-linearity refers to the Best Straight Line fit measured for offset pressure, full scale pressure and 1/2 full scale pressure.
Thermal effects tested and guaranteed from 0 - 70°C relative to 25°C. All specifications shown are relative to 25°C.
Change in output after one year or 1 million pressure cycles.
5.
6.
7.
8.
9.
March 2006 / 002
3/6