130-160MT..KB Series
Bulletin I27502 rev. A 05/03
500
450
400
350
300
250
200
150
100
50
R
t
130MT..KB Series
= 150°C
h
S
A
T
J
=
0
.
0
5
K
/
W
120°
(Rect)
-
D
e
l
t
a
R
0
.
5
K
/
W
0
0
20 40 60 80 100 120 140 1060
Total Output Current (A)
25
50
75
100
125
150
Maximum Allowable Ambient Temperature (°C)
Fig. 3 - Total Power Loss Characteristics
1000
900
800
700
600
500
400
300
200
1200
1100
1000
900
800
700
600
500
400
300
200
At Any Rated Load Condition And With
Maximum Non Repetitive Surge Current
Versus Pulse Train Duration.
Rated V
Applied Following Surge.
RRM
Initial T = 150°C
Initial T = 150°C
J
J
No Voltage Reapplied
@ 60 Hz 0.0083 s
@ 50 Hz 0.0100 s
Rated V
Reapplied
RRM
130MT..KB Series
130MT..KB Series
1
10
100
0.01
0.1
Pulse Train Duration (s)
1
Number Of Equal Amplitude Half Cycle Current Pulses (N)
Fig. 4 - Maximum Non-Repetitive Surge Current
Fig. 5 - Maximum Non-Repetitive Surge Current
150
1000
160MT..KB Series
140
130
120
110
100
90
100
10
1
120°
(Rect)
T
= 25°C
J
T
= 150°C
J
80
70
160MT..KB Series
Per Junction
60
50
0
40
80
Total Output Current (A)
Fig. 6 - Current Ratings Characteristics
120
160
200
240
0
1
2
3
4
5
Instantaneous Forward Voltage (V)
Fig. 7 - Forward Voltage Drop Characteristics
www.irf.com
5