M10-DATASHEET
2015.05.04
4
Recommended Operating Conditions
Condition (V)
Overshoot Duration as % of High Time
Unit
4.57
0.2
%
Recommended Operating Conditions
This section lists the functional operation limits for the AC and DC parameters for MAX 10 devices. The tables list the steady-state voltage values
expected from MAX 10 devices. Power supply ramps must all be strictly monotonic, without plateaus.
Single Supply Devices Power Supplies Recommended Operating Conditions
Table 6: Power Supplies Recommended Operating Conditions for MAX 10 Single Supply Devices—Preliminary
Symbol
Parameter
Condition
Min
Typ
Max
Unit
(1)
VCC_ONE
Supply voltage for core and periphery
through on-die voltage regulator
—
2.85/3.135
3.0/3.3
3.15/3.465
V
3.3 V
3.0 V
2.5 V
1.8 V
1.5 V
1.35 V
1.2 V
—
3.135
2.85
3.3
3
3.465
3.15
V
V
V
V
V
V
V
V
2.375
2.5
2.625
Supply voltage for input and output
buffers
(2)
VCCIO
1.71
1.8
1.89
1.425
1.5
1.575
1.2825
1.14
1.35
1.2
1.4175
1.26
(1)
VCCA
Supply voltage for PLL regulator and
ADC block (analog)
2.85/3.135
3.0/3.3
3.15/3.465
(1)
(2)
VCCA must be connected to VCC_ONE through a filter.
VCCIO for all I/O banks must be powered up during user mode because VCCIO I/O banks are used for the ADC and I/O functionalities.
MAX 10 FPGA Device Datasheet
Send Feedback
Altera Corporation