LFP0500-A4BMB | LFP Cubic
LEVEL SENSORS
Ordering information
A
B
C
D
E
F
Type
LFP0500-A4BMB
Part no.
1071078
Other models and accessories www.sick.com/LFP_Cubic
Illustration may differ
Detailed technical data
Features
Fluids
Medium
H
I
Switch, Continuous
Measurement
Design
Remote amplifier, length of cable 1 m
Mono rod probe
Probe type
500 mm
Probe length
Process pressure
Process temperature
GOST approval
RoHS certificate
IO-Link
J
–1 bar ... 10 bar
–20 °C ... +100 °C
✔
✔
✔
✔
K
L
CULus certificate
Performance
M
N
O
P
Q
R
S
T
± 5 mm 1)
≤ 2 mm
Accuracy of sensor element
Repeatability
< 2 mm
Resolution
< 400 ms
Response time
Dielectricity constant
≥ 5 for mono rod probe / rope probe
≥ 1.8 with coaxial tube
No limitation
≤ 500 mm/s
Conductivity
Maximum level change
Deactivated area at end of probe
10 mm 1)
194.3 years (EN ISO 13849-1)
MTTF
1)
With water under reference conditions.
2
FLUID SENSORS | SICK
Online data sheet | 2016-05-11 15:58:08
Subject to change without notice