JNPS-0814
Table 1: ENVIROMENTAL TEST
ITEM
TEST CONDITION
RELATED STANDARD
MIL-STD-202F106D
MOISTURE
SALT SPRAY
-10 ∼ 65°C, Relative Humidity 95% / 10 cycles
NaCl 5% solution, 35°C / 48 hours
MIL-STD-202F101D
MIL-STD-202F107G
MIL-STD-202F103B
――――
THERMAL SHOCK
-55°C→25°C→85°C→25°C / 5 cycles
HUMIDITY
40°C, Relative Humidity 95% / 96 hours
(STEADY STATE)
THERMAL LIFE
H2S GAS
Steady Current: Current Rating × 110%, 85°C / 1000 hours
3 ± 1 ppm, 40°C, Relative Humidity 70 ∼ 80% / 96 hours
JEIDA-38-1984
Sweep Freq.: 10 ∼ 55Hz, Amplitude: 1.52mm (or 98 m/s2)
Sweep Cycle: 1 min., Sweep time: 2 hours
Sweep Directions: X, Y, Z
490 m/s2, 11ms, Half sine shock pulse.
3 times / X,Y,Z directions (Total 9 times)
VIBRATION
MIL-STD-202F201A
MIL-STD-202E213B
MECHANICAL
SHOCK
7. PLATING SPEC INDICATION ON CONNECTOR
The first letter, in stamped 3 letters on the connector body for lot numbering, identified the following
plating specs.
R XX : PL plating
Z XX : PE plating
Y XX : PC plating
* XX : two alphabet letters
8. PACKAGE & IDENTIFICATION
These products are packed with plastic tray and carton box for transit.
Carton box is identified by part number, quantity, maker name and lot number.
9. STORAGE
This products shall be stored in a room, ambient temperature 5 ∼ 35°C, and ambient humidity
40 ∼ 70%.
10