Applications  
Maximum Single lmpulse Dischrge Current  
This test is to determine the ability of the GTA to  
conduct a maximum single impulse Discharge  
current. The current impulse waveform is 8/ 20s.  
The maximum single impulse discharge current  
is the crest current of the impulse.  
1. Protection for telephone set, facsimile, telex,  
telephone system, CATV, computer and peripheral  
equipment.  
2. Semiconductor circuit protection in equipment  
that also uses high voltage such as TV,  
oscilloscope, and electron microscope.  
3. Automatic control of luminous energy in  
stroboscopic tube.  
GASTUBE  
ARRESTER  
Capacitance  
The capacitance of the GTA is defined as  
capacitance across terminals of the GTA at 1 kHz.  
Operating Temperature Range  
Gas tube arrester(GTA)is a surge absorber  
featuring low capacitance and high surge  
absorption energy.  
4. Generator of high-voltage for gas igniter.  
20C65C  
DC Holdover Voltage  
Voltage-Current Characteristics  
lt consists of a sealed tube in which inert  
gas is injected and electrodes which are  
set at fixed intervals. The simple structure  
and the dimensional accuracy offer high  
reliability and stabilized characteristics.  
The current through the GTA is changed over the  
range of values of 1018 to 102 amps which is shown  
as the figure below and the voltage across the GTA will  
also valy.The discharge characteristics are changed to  
various mode by the flowing current, and the final  
mode of the discharge characteristics is arc discharge .  
This values is defined as the maximum DC voltage  
across the terminals of the GTA which is expected  
to clear and restore its high impedance state within  
150 ms or less after the passage of a surge.  
loc  
li  
Ro  
Non self  
sustaining  
D
D
Townsent  
Glow  
R
abnomalous  
glow  
V
2
1
V
T
b
c
f
C
d
e
1. DC constant-voltage regulated power supply  
2. lmpulse generator  
Arc  
g
Ro  
R
C
: DC current adjustment resistor  
: Line mimic resistor 136 Ohms  
: Line mimic capacitor 0.083F  
104105  
A
a
1016  
1A  
A
D
: lnsulation diode  
Current  
Impulse Waveform  
When the applied voltage across the GTA exceeds  
the breakdown voltage (sparkover voltage), the  
current through the GTA increases rapidly to value  
of several amps or greater. The rate of current rise and  
level to be reached are limited by the series impedance  
of the circuit.The voltage across the GTA at this  
time is very low with typical value of 20 to 30 volts.  
lmpulse breakdown voltage is the voltage at which  
the GTA fires when the voltage increases at rates  
of more than 100V/s. This value may not vary even  
after the GTA has been stored in the dark for long  
period. The value of the impulse breakdown voltage  
increases with increasing steepness of the surge  
voltage as the figure below.  
Electrical Characteristics  
AC Discharge Current  
The current is the rms value of sinusoidal alternating  
current of 50Hz or 60Hz which can flow through the  
GTA in accordance with a certain test method without  
substantially altering its sparkover voltage. The  
usual test consists of specified loads applied for 1  
sec at interval of 1 min alternately. ln the test of the  
maximum AC discharge current, the GTA is applied  
9 cycles of 50Hz AC(180 ms) continuously.  
100  
90  
50  
10  
lmpulse Surge Life  
The life is defined as the minimum number of surges  
of a certain current waveform the GTA can survive  
without deterioration of its operating specifications.  
lnsulation Resistance  
Tf  
Time (s)  
Tt  
This is defined as the resistance value across the  
terminal of GTA at 100VDC for devices over 230VDC  
(140VDC for GTA type) breakdown voltage and 50VDC  
for devices less than 230VDC(140VDC for GTA type)ratings.  
DC Breakdown Voltage  
The voltage is the minimum slowly rising DC voltage that  
will cause sparkover when applied across the terminal  
of the GTA.The GTA shall be placed in darkness for  
at least 15 min and tested in this condition using a  
ramp voltage waveform with 100V/s to 500V/s.  
The GTA shall be tested with a positive and a  
negative waveform. The sparkover current for DC  
sparkover voltage test shall be within 10 amps.  
Impulse Breakdown Voltage  
The GTA to be exposed to the test shall be kept in  
total darkness before (for at least 15 min) and during  
the test. Then, with a ramp voltage with 5kV/s  
applied to the GTA, the breakdown voltage level is  
recorded. ln case of testing with opposite polarity,  
using the same GTA, a minimum of 15 min shall  
elapse.  
40  

与100BT-5相关器件

型号 品牌 获取价格 描述 数据表
100BT-6 ETC

获取价格

THERMOPILE TYPE INFRARED SENSOR
100C0285 DAICO

获取价格

SP3T Relay
100C0347 DAICO

获取价格

Transfer Switch
100C0347-BNC12 DAICO

获取价格

Transfer Switch
100C0347-BNC18 DAICO

获取价格

Transfer Switch
100C0347-BNC26 DAICO

获取价格

Transfer Switch
100C0347-BNC-6 DAICO

获取价格

Transfer Switch
100C0347-SMA12 DAICO

获取价格

Transfer Switch
100C0347-SMA18 DAICO

获取价格

Transfer Switch
100C0347-SMA26 DAICO

获取价格

Transfer Switch