Instruction Sheet  
Crimping Dies for SOLISTRAND*  
and STRATO-THERM* Terminals  
and Butt Splices  
408-2648  
17 MAY 13 Rev C  
Refer to machine manual for crimp instructions.  
1. INTRODUCTION  
This instruction sheet provides instructions on product  
application; and maintenance and inspection  
procedures for crimping dies 69930, 69931, 69932,  
69954, 69955, and 69956 used in the  
AMP-TAPETRONIC* machine 69875; dies 68240-1,  
68241-1, and 68242-1 are also used in the  
AMP-TAPETRONIC machine 69875, or the Model “K”  
AMP-O-LECTRIC* 565435-5, or the G-Terminating  
Machine 354500-1.  
3. CRIMP INSPECTION  
Inspect crimped terminals and splices by checking the  
features described in Figure 2. Use only the terminals  
and splices that meet the conditions shown in the  
“ACCEPT” column.  
“REJECT” terminals and splices can be avoided  
through careful use of instructions provided in the  
machine manual and by preforming regular die  
maintenance as instructed in Section 4,  
MAINTENANCE/INSPECTION PROCEDURE, of this  
instruction sheet.  
These dies are used to crimp:  
SOLISTRAND terminals and butt splices on solid  
or stranded copper wire sizes 22 thru 10.  
Uninsulated STRATO-THERM terminals and butt  
splices (with wire insulation support) on solid or  
stranded copper wire sizes 22 thru 10.  
4. MAINTENANCE/INSPECTION PROCEDURE  
It is recommended that a maintenance/inspection  
program be performed periodically to ensure  
dependable and uniform terminations. Dies should be  
inspected at least once a month. Frequency of  
inspection may be adjusted to suit your requirements  
through experience. Frequency of inspection is  
depend upon:  
Uninsulated STRATO-THERM terminals and butt  
splices (without wire insulation support) on solid or  
stranded copper wire sizes 22 thru 10.  
Dies are coated with preservative to prevent rust and  
corrosion. Wipe preservative from dies, particularly  
from crimping surfaces.  
1. The care, amount of use, and handling of the  
dies.  
Die insertion and removal and crimping instructions  
are provided in the manual packaged with the  
terminating machine. Section 2, INSTRUCTIONS,  
provides personal safety and wire preparation  
information. Section 3, CRIMP INSPECTION, features  
terminal and splice crimp inspection procedures which  
will enable you to establish and maintain a die  
certification program.  
2. The degree of operator skill.  
3. The presence of abnormal amounts of dust and  
dirt.  
4. Your own established standards.  
Since there is a possibility of die damage in shipment,  
new dies should be inspected in accordance with  
Section 4 when received in your plant.  
For further instructions relative to the machines,  
tooling adjustment, tape loading, etc., refer to the  
instructions packaged with the machines.  
NOTE  
NOTE  
i
4.1. Cleaning  
Dimensions in this instruction sheet are in millimeters  
[with inches in brackets]. Figures and illustrations are for  
reference only and are not drawn to scale.  
Do NOT allow deposits of dirt, grease, and foreign  
matter to accumulate on the die closure surfaces and  
on the bottoming surfaces of the dies. These deposits  
may prevent the dies from bottoming fully and may  
also cause excessive wear in the die closure surfaces,  
thereby affecting the quality of the crimp. The dies  
should be wiped clean frequently with a clean cloth.  
Reasons for reissue of this instruction sheet are  
provided in Section 5, REVISION SUMMARY.  
2. INSTRUCTIONS  
DANGER  
Avoid personal injury. Always disconnect machine from  
!
4.2. Visual Inspection  
power supply when preforming adjustments, die  
installation or removal, and machine maintenance.  
Always keep guards and covers in place during normal  
machine operation.  
Visually inspect the die closure surfaces for chipped or  
pitted conditions. Although dies may gage within  
permissible limits, worn or damaged die closure  
surfaces are objectionable and can affect the quality of  
the crimp. Examples of possible damaged die  
surfaces are shown in Figure 3.  
For wire preparation, select the correct wire strip  
length from Figure 1. Do NOT use wires with nicked or  
missing conductor strands.  
©2013 Tyco Electronics Corporation, a TE Connectivity Ltd. company TOOLING ASSISTANCE CENTER 1-800-722-1111 This controlled document is subject to change.  
1 of 6  
All Rights Reserved  
*Trademark  
PRODUCT INFORMATION 1-800-522-6752  
For latest revision and Regional Customer Service,  
visit our website at www.te.com  
TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product and/or company names may be trademarks of their respective owners.  

与1-307161-8相关器件

型号 品牌 描述 获取价格 数据表
1-307161-9 TE The care, amount of use, and handling of the dies.

获取价格

13071A DIALIGHT LED Mini Marker/ Clearance Lamps

获取价格

13071R DIALIGHT LED Mini Marker/ Clearance Lamps

获取价格

1307-25-D2-30-010 ECS Card Edge Connector

获取价格

1-307275-0 TE Application and Maintenance for Crimping Die Assemblies for Tape-Mounted PIDG and PLASTI-G

获取价格

1-307275-1 TE Application and Maintenance for Crimping Die Assemblies for Tape-Mounted PIDG and PLASTI-G

获取价格