ISOLATED DC/DC CONVERTERS
36 Vdc - 75 Vdc Input 14 Vdc /10A Output, 1/4 Brick Converter
Oct. 07, 2011
Output Specifications (continued)
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Parameter
Min
Typ
Max
Unit
Notes
Output Ripple and Noise(pk-pk)
under worst case
over all operating input voltage, load
and ambient temperature condition
220
mV
Output Current Range
Output DC Current Limit
Short Circuit Surge Transient
Rise Time
0
10
14
5
A
A
10.5
12
A2s
12
60
50
3
mS
6
30
25
0
mS Enable from Vin
Turn on Time
mS Enable from on/off
Overshoot at Turn on
Output Capacitance
Transient Response
%
0
680
uF
Overshoot
Settling Time
Overshoot
-
-
-
-
400
200
400
200
600
300
600
300
mV
△V25%~50% of
di/dt=0.1A/us, Vin=48 Vdc, with a 1 µF
Max Load
uS
mV
uS
ceramic capacitor and a 10 uF
Tantalum capacitor at output,
Ta=25 °C.
△V50%~25% of
Max Load
Settling Time
Note: All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
General Specifications
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
91.5
93.5
-
%
Vin=48V, full load, Ta=25°C
Switching Frequency
-
-
250
125
-
-
kHz
Over Temperature Protection
°C
This voltage is achieved by trimming
up output slowly
Over Voltage Protection(Static)
Weight
-
-
17
48
-
-
V
g
Calculated Per Bell Core SR-332
(Vin=48V, Vo=12V, Io=9.6A, Ta = 25
°C, FIT=109/MTBF)
FIT
TBD
-
-
Dimensions
Inches (L × W × H)
Millimeters (L × W × H)
2.30 x 1.45 x 0.50
58.42 x 36.83 x 12.69
Isolation characteristics
Input to Output
-
-
1500
V
V
Input to Case
-
-
1500
Output to Case
-
10M
-
-
-
500
V
Isolation Resistance
Isolation Capacitance
-
-
ohm
pF
3900
Note: All specifications are typical at 25 °C unless otherwise stated.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
3