ISOLATED DC/DC CONVERTERS
36 Vdc - 75 Vdc Input
1.2 Vdc /60 A, 3.3V/60A Outputs
Feb 10, 2010
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Output Specifications
Parameter
Min
Typ
Max
Notes
Output Voltage Set Point
Vo=1.2V
Vo=3.3V
1.176 V
3.234 V
1.2 V
3.3 V
1.224 V
3.366 V
Vin=48 V, Io=50%Load
Line Regulation
Load Regulation
Vo=1.2V
Vo=3.3V
-
-
2 mV
5 mV
5 mV
10 mV
Vin=36-75 V, full load
Vin=48 V, Iout=0-60 A
Vin=48 V, Iout=0-60 A
Vo=1.2V
Vo=3.3V
-
-
5 mV
8 mV
10 mV
15 mV
Regulation Over Temperature
(-40 C to 85 C)
-
-
-
-
10 mV
20 mV
Vo=1.2V
Vo=3.3V
Output Current
0 A
-
60 A
85 A
Current Limit Threshold
Ripple and Noise (pk-pk)
65 A
75 A
Vo=1.2V
Vo=3.3V
-
-
60 mV
60 mV
100 mV
100 mV
0-20MHz BW, with a 1µF
ceramic capacitor and a 10uF
Tantalum cap at output.
Ripple and Noise (rms)
Ripple and Noise (pk-pk)
Vo=1.2V
Vo=3.3V
-
-
15 mV
15 mV
30 mV
40 mV
over all operating input voltage,
load and ambient temperature
condition
Vo=1.2V
Vo=3.3V
-
-
-
-
150 mV
150 mV
Rise Time
Vo=1.2V
Vo=3.3V
0.5 mS
5 mS
-
-
5 mS
10 mS
Turn on Time
Vo=1.2V
Vo=3.3V
-
-
30 mS
30 mS
50 mS
50 mS
Enable form Vin and ON/OFF
Overshoot at Turn on
Output Capacitance
-
-
3%
Vo=1.2V
Vo=3.3V
0
470
-
-
30,000 uF
20,000 uF
Transient Response
Overshoot
Settling Time
Overshoot
-
-
-
-
-
-
-
-
60 mV
120 mV
50% ~ 75%
Max Load
150 uS
60 mV
150 uS
60 mV
150 uS
60 mV
150 uS
200 uS
120 mV
200 uS
120 mV
200 uS
120 mV
200 uS
VO=1.2 V
75% ~ 50%
Max Load
Settling Time
Overshoot
di/dt=0.1A/us, Vin=48Vdc,
Ta=25 °C
50% ~ 75%
Max Load
Settling Time
Overshoot
VO=3.3 V
75% ~ 50%
Max Load
Settling Time
Note: All specifications are typical at nominal input, full load at 25 C unless otherwise stated.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com