https://www.phoenixcontact.com/us/products/3210306
Disconnect terminal block - PT 1,5/S-TG - 3210306
Technical data
General
Result of aging test
Test passed
Ageing test for screwless modular terminal block temperature cycles
Result of thermal test
192
Test passed
Proof of thermal characteristics (needle flame) effective duration
Oscillation, broadband noise test result
Test specification, oscillation, broadband noise
Test spectrum
30 s
Test passed
DIN EN 50155 (VDE 0115-200):2008-03
Service life test category 2, bogie mounted
f1 = 5 Hz to f2 = 250 Hz
Test frequency
6.12 (m/s2)2/Hz
ASD level
Acceleration
3.12 g
Test duration per axis
Test directions
5 h
X-, Y- and Z-axis
Shock test result
Test passed
Test specification, shock test
Shock form
DIN EN 50155 (VDE 0115-200):2008-03
Half-sine
Acceleration
30g
Shock duration
18 ms
Number of shocks per direction
Test directions
3
X-, Y- and Z-axis (pos. and neg.)
130 °C
Relative insulation material temperature index (Elec., UL 746 B)
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
Static insulating material application in cold
Behavior in fire for rail vehicles (DIN 5510-2)
Flame test method (DIN EN 60695-11-10)
-60 °C
Test passed
V0
Oxygen index (DIN EN ISO 4589-2)
>32 %
NF F16-101, NF F10-102 Class I
2
NF F16-101, NF F10-102 Class F
2
Surface flammability NFPA 130 (ASTM E 162)
Specific optical density of smoke NFPA 130 (ASTM E 662)
Smoke gas toxicity NFPA 130 (SMP 800C)
Calorimetric heat release NFPA 130 (ASTM E 1354)
Fire protection for rail vehicles (DIN EN 45545-2) R22
Fire protection for rail vehicles (DIN EN 45545-2) R23
Fire protection for rail vehicles (DIN EN 45545-2) R24
Fire protection for rail vehicles (DIN EN 45545-2) R26
passed
passed
passed
28 MJ/kg
HL 1 - HL 3
HL 1 - HL 3
HL 1 - HL 3
HL 1 - HL 3
Dimensions
09/06/2016 Page 3 / 22