ISOLATED DC/DC CONVERTERS
18 Vdc - 62.5 Vdc Input 3.3 Vdc /12.1 A Output
Input Specifications (continued)
Parameter
Min
Typ
Max
Notes
I2t Inrush Current Transient
-
0.05 A2s
0.1 A2s
Turn-on Voltage Threshold
Turn-off Voltage Threshold
Input Over Voltage Lockout
16.0 V
15.5 V
75 V
16.5 V
16.0 V
76 V
17.0 V
16.5 V
77 V
Output Specifications
Parameter
Min
Typ
Max
Notes
Output Voltage Set Point
Load Regulation
3.25 V
3.30 V
±3 mV
±3 mV
3.35 V
±10 mV
±10 mV
Vin=48 V, Io=50% load
-
-
line Regulation
Regulation Over Temperature
(-40deg.C-85deg.C)
-
-
-
-
±30 mV
10 mV
30 mV
5 mV
±50 mV
15 mV
40 mV
10 mV
Ripple and Noise (rms)
Ripple and Noise (pk-pk)
Ripple and Noise (pk-pk)
0-20 MHz BW, with a 10 µF tantalum
cap and a 0.1µF ceramic cap at the
output.
0-20 MHz BW, with a 300 µF ceramic
capacitor at the output.
Output Current Range
Output DC Current Limit
Short Circuit Surge Transient
Turn on Time
0 A
-
18 A
3 A2s
-
12.1 A
-
5 A2s
50 mS
4%
-
Vin=48 V , in Latch mode
-
10 mS
-
Overshoot at Turn on
0%
-
Output Capacitance
0 uF
4800 uF
Transient Response
Overshoot
Settling Time
Overshoot
-
-
-
-
100 mV
400 uS
100 mV
400 uS
130 mV
100% ~ 50%
Max Load
di/dt=1 A/us, Vin=24 Vdc,
Ta=25 °C, with a 300 µF
ceramic capacitor at output.
1000 uS
130 mV
1000 uS
50% ~ 100%
Max Load
Settling Time
Note: All specifications are typical at 25 °C unless otherwise stated.
General Specifications
Parameter
Min
Typ
Max
Notes
Efficiency
Vin=24 V
Vin=48 V
89%
88%
90.5%
89.5%
-
-
Measured at normal Vin, full load.
Switching Frequency
Isolation capacitance
310 kHz
-
330 kHz
1500 pF
350 kHz
-
The total voltage increased by trim and
remote sense should not exceed
10%Vo.
Remote Sense Compensation
Output Voltage Trim Range
-
-
-
10%
90%
110%
Over Temperature Protection
Over Voltage Protection
-
-
-
-
125 °C
3.87 V
Vin=48 V, full load, in Latch mode.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com