Cannon VG/CA-Bayonet
Electrical Data
Contact resistance
(Millivolt test)
Contact rating at 68 °F (+20 °C)
The contact resistance has to be tested according to VG95234
part 2, test no. 5.10.1 and VG 95210, part 37. The measuring
points are indicated in the illustration.
Contact size
max. current
A
10
8
16S/15S
16/15
12/25
8/60/100
4/160
0/500
22
22
41
74
135
245
Current rating
depending on ambient temperature
Contact size
metric
Max. contact
resistance
mΩ
AWG
10
15S/15
25
60/100
160
500
–
12
6
16S/16
12
8
3
1
0,5
0,2
4
0
Insulation resistance
Acc. to VG95319, part 2, test no. 5.12 and VG95210, part 32,
test condition B
Standard insulator material
FKM insulator material (upon request)
> 1000 MΩ
> 5000 MΩ
Test voltage
Acc. to VG95319, part 2, test no. 5.13 and VG 95210, part 31
Test voltage for service rating:
Service rating
Test voltage V
rms
Instruments
1050
1600
4000
2500
3000
A
B
D
E
Operating voltage and connector usage
Connectors in equipments must not be separated or mated
under load when used per specifications.
Air and creepage paths (min.)
As according to specification the connectors are suitable for an
operating voltage of 50 V (see Product Safety Information).
However, this is only valid, when the connectors are freely
accessible during operation and consequently might be
touchable. When the connectors will be operated with line
voltage, please contact ITT Customer Service.
Voltage class
Instr.
0,7
A
D
E
Air and creepage paths mm
1,1
2,8
4,8
Dimensions shown in mm
Specifications and dimensions subject to change
www.ittcannon.com
4