ZWS Series
Single Output, 3.3W to 50W Power Supplies
Features
u Universal Input (85 - 265VAC)
u Input transient protected
u 2 year warranty
u High quality design
u Peak Power capability
Key Market Segments & Applications
Specifications
ZWS5
ZWS10
ZWS15
ZWS30
ZWS50
Model
AC Input Voltage range
DC Input Voltage range
Inrush Current (100/200VAC) (1)
Temperature Coefficient
Overcurrent Protection (2)
Overvoltage Protection
Hold Up Time (Typ) @ 100VAC
Remote Sense
-
-
A
-
85-265VAC (47-440Hz)
110 - 330VDC
15 / 30
<0.02%/ºC
~125%
-
V
ms
-
~140% diode clamp
~115 - 130%, manual reset
17
None
Operating Temperature
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
°C
°C
°C
-
(open frame) -10ºC~+60ºC, derate linearly to 70% load from 50ºC~60ºC
(with cover) Additional derating applies, please consult Installation Manual
-30 to +85ºC
10 - 95% RH
Convection
-
Withstand Voltage
-
Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA),
Output to Ground 500VAC (100mA) for 1 min.
>100M at 25°C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour
< 196.1 m/s2
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Conducted & Radiated
Recommended EMI Filter
-
-
-
-
UL60950-1, CSA60950-1, EN60950-1, CE Mark
EN55022-B, FCC Class B, VCCI-B
EM
-
RSEL-20R5W
120/120
RSEL-2001W
RSEL-2002W
140/270
RSEL-2002W
Weight (Typ)
Size (WxHxD)
Warranty
g
mm
yrs
370
See Outline Drawings
2 years
Notes:
(1) 25°C ambient (cold start)
(2) Avoid prolonged operartion in overload
1-800-526-2324 • www.us.tdk-lambda.com/lp/
113
Disclaimer: us.tdk-lambda.com/lp/legal.htm