ZWQ Series
80W to 170W Quad Output Power Supplies
Features
u Universal Input (85 - 265VAC)
u Power Factor Corrected
u Floating Adjustable Fourth Output
u Low Profile <1U High
Key Market Segments & Applications
Specifications
ZWQ80
-5222
ZWQ80
-5223
ZWQ80
-5224
ZWQ80 ZWQ130 ZWQ130 ZWQ130 ZWQ130
Model
-5225
-5222
-5223
-5224
-5225
Input Voltage
Input Current (1)
Inrush Current (1)
Power Factor
Temperature Coefficient
Max Output Power (convection)
Max Output Power (forced air)
Overpower Protection (2)
Minimum Load
Output Voltage Accuracy
Efficiency (Typ)
Hold Up Time (1)
-
A
A
-
85-265VAC (47-63Hz), 120-370VDC
1.6 / 0.8
2.6 / 1.3
14/28
Meets EN61000-3-2
<0.02%/°C
-
W
W
W
A
%
%
ms
-
80
130
104
>109
88.7
>93
104
>109
104
>109
170
>173
149.6
>152
170
>173
170
>173
V1: 0.9A Conv, 1.4A Forced Air
V1: 1.5A Conv, 2.1A Forced Air
±5% for outputs V2 and V3
72
20
Leakage Current
Remote On / Off
0.75mA max, 0.2mA (Typ) at 100VAC / 0.44mA(Typ) at 230VAC
See installation manual (Not available with /A cover option)
-10°C to 60°C, derate linearly to 50% load from 40°C to 60°C. (3)
-10°C to 70°C, derate linearly to 50% load from 50°C to 70°C. (>30cfm airflow)(3)
-30° to +85°C
-
Oper Temp (convection cooled)
Oper Temp (forced air cooled)
Storage Temperature
Humidity (non condensing)
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
°C
°C
°C
-
-
-
Operating: 30 - 90% RH; Non-operating 10-95% RH
I/P~Grnd 2kVAC (20mA), I/P~O/P 3kVAC (20mA), O/P~Grnd 500VAC (100mA) for 1 min.
>100M at 25°C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour
< 196.1 m/s2
-
-
Safety Agency Approvals
Conducted & Radiated EMI
Immunity
-
-
-
UL60950-1, CSA60950-1, EN60950-1, CE Mark, EN50178
EN55011, EN55022-B, FCC Class B, VCCI-B
EN61000-4-2,-3,-4,-5,-6,-8,-11
Weight (Typ)
g
550
730
Size (W x H x D)
Warranty
mm
yrs
93.5 x 35 x 210 (refer to outline drawing)
106 x 35 x 225 (refer to outline drawing)
One Year
(1) 100/200VAC
(2) Avoid prolong operation in overload
(3) /A version - additional derating, see installation manual
1-800-526-2324 • www.us.tdk-lambda.com/lp/
111
Disclaimer: us.tdk-lambda.com/lp/legal.htm