• Constant Voltage / Constant Current
• Last Setting Memory
• Digital Meters
• Built-in RS232 & RS485
• Bench or Rack Mount
• Embedded Microprocessor Controller
• Voltage up to 120V, Current up to 132A
ZUP Series
Zero Up Programmable Power Supplies
Specifications
MODELS
ZUP6
ZUP10
ZUP20
ZUP36
ZUP60
ZUP80
ZUP120
ITEMS
Cond.
CV
CV
CV
CV
Load Regulation
Line Regulation
Recovery Time (1)
Temperature Coefficient
Temperature Drift (2)
2mV + 0.005% over 0 - 100% load change
1mV + 0.005% over 85 - 132 or 170 - 265VAC constant load
1ms
0.5ms
0.2ms
30ppm/°C following 30 minute warm up
0.01% + 2mV change in output
50 - 60ms
CV
Up programming response time
Down prog. resp. time (CV)
Down prog. resp. time (CV)
CV
Full
Zero
80ms
120ms
50ms (70ms ZUP60-14)
250ms
350ms
400ms
500ms
750ms
800ms
1000ms
Load Regulation
Line Regulation
CC
CC
CC
CC
-
-
-
-
V
-
0.01% + 5mA on 200W and 400W models, 0.07% + 10mA on 800W models
0.01% + 2mA on 200W and 400W models, 0.01% + 5mA on 800W models
100ppm/°C from rated current after 30 minute warm up time
0.02% + 5mA, 200W and 400W models, 0.05% + 10mA, 800W models
Better than 0.028% of rated voltage
Temperature Coefficient
Temperature Drift (2)
Prog Voltage resolution
Prog Voltage accuracy
Prog Current resolution
Prog Current accuracy
Overvoltage Shutdown
Thermal Protection
.02%+5mV. .02%+8mV.
.02%+12mV .02%+20mV
.02%+35mV .02%+50mV .02%+80mV
Better than 0.03% of rated current
0.4% + 40mA
0 - 7.5
0 - 13
0 - 24
0 - 40
0 - 66
0 - 88
0 - 132
Over temperature protected
Display - Voltage
Display - Current
Display - Status
Remote On/Off
-
-
-
-
3 digits (6, 20, 36, 60, 80V models), 3.5 digits (10, 120V models). Accuracy 0.2% ± 2 digits
3 digits, (3.5 digits 132A model). Accuracy 0.5% ± 3 digits
CV / CC, Alarm, Foldback, Local/Remote, On/Off
TTL signal or dry contact relay
Output Good
-
Open Collector
Voltage & Current Programming
Remote Sense
-
-
-
-
-
-
ms
-
-
-
-
By either Voltage (0-4V) or Resistance (0-4k)
Up to 0.5V compensation per output cable
RS232 & RS485 standard
Communication Interface
Series & Parallel Operation
AC Input Voltage range
Inrush Current (100/200VAC) (3)
Hold Up Time (Typ) at 100VAC
Power Factor Correction
Temperature Range
Humidity (non condensing)
Cooling
Series: Up to two units; Parallel: Up to five units in master-slave configuration
85-265VAC (47-63Hz)
15/30A, 200W models, 15A, 400W models, 30A, 800W models
20
Complies with EN61000-3 Class A (0.99 typ)
Operating: 0°C - 50°C; Storage: -20°C to +70°C
Operating: 30°C - 90% RH, Storage 10°C - 95%RH
Internal fan
Withstand Voltage
-
Ω
-
-
-
Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
>100MΩ at 25°C & 70%RH
Vibration:10-55Hz(1 min.) 2G constant X, Y, Z, when correctly mounted; Shock: <20G
UL3111-1, EN61010-1, CE Mark
Isolation Resistance
Vibration & Shock (non-op.)
Safety Agency Approvals
Conducted & Radiated EMI
EN55022-B conducted, A radiated, FCC Class B conducted,
A radiated, VCCI-B conducted, -A radiated
3
Warranty
yrs
(1) Recovery to within +/-50mV after load change of 50-100% (2) Over 8 hour period following 30 minute warm up time (3) 25°C ambient (cold start)
1
ZUP Series