• PFC
• Wide Range AC Input
• Low Profile, Industry Standard Footprint
• Global Safety Agency Compliance
• RoHS Compliant
Key Market Segments & Applications
Video/Audio Routers
Datacom
Point of Sale
Test and Measurement
LED Information Displays
ZPSA100 Series
3" x 5" 100W AC-DC
Power Supplies
ZPSA100 Features and Benefits
Features
Benefits
• Industry Standard Footprint
• Up to 90% efficiency
• Broad Product Range
• Meets EN61000-4 Immunity
• Low Profile
• Available to Second Source
• Less System Heating
• Optimization of Power Supply to System
• Greater Reliability
Specifications
MODEL
ZPSA100
ITEMS
Input Voltage range
Inrush Current
Input Current (115/230VAC)
Temperature Coefficient
Voltage Accuracy
Minimum Load
-
A
A
-
-
A
-
90 - 264VAC (47 - 440Hz) or 120 - 370VDC
25 / 50 (cold start)
1.1 / 0.6
0.05%/°C
1%
None
Load Regulation
1%
Line Regulation
Ripple & Noise
-
0.5%
(1)
mV
-
V
ms
°C
°C
-
1% (for 5V, 2% or 50mV whichever is greater)
Short Circuit Protection
Overvoltage Protection
Hold Up Time (Typ)
Operating Temperature
Storage Temperature
Humidity (non condensing)
Foldback
Typically 110-130% of nominal, auto recovery
16ms at 115VAC input
0 to +70°C with derating/air flow
-20 to +85°C
10 - 95% RH
Cooling
(2)
-
Convection/air flow
Input to Ground 1.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
>100MΩ at 25°C & 70%RH, Output to Ground 500VDC
23.52m/s2 (10 - 55Hz: constant sweep 1 min X, Y, Z for 1 hour)
< 196.1 m/s2 (20G)
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Conducted & Radiated EMI
Immunity
-
-
-
IEC/UL/CSA/EN62368-1, 60950-1, CE Mark
EN55022-B, FCC Class B
-
EN61000-4-2,-3,-4,-6,-8
Weight (Typ)
Size (WxLxH)
Warranty
g
mm
yrs
385
127 X 76.2 X 26.6 (including underside components )
2
Notes:
(1) 5V measured with 0.1µF ceramic & 220µF electrolytic at 20MHz BW, all other models measured with 0.1µF & 10uF ceramic electrolytic at 20MHz BW.
(2) 70°C operating with 100LFM air flow.
1