ZMS100 Series
www.emea.tdk-lambda.com/zms
80W Convection, 100W
Forced-Air Cooled
/('
,QGXVWULDO
7HVW
%URDGFDVW
0HGLFDO
&RPP
Single Output Power Supplies
Featuresꢀ
Benefitsꢀ
• Long e-cap lifetime
• Better field reliability and service life
• Space saving in end equipment
• Compact 2 x 4 inch footprint
• Medical approval with 2 x MoPP isolation
• Suitable for B and BF type medical equipment
• Suitable for Class I and Class II installations • Flexible utilisation
• Ceramic start-up cap
• Eradicates start-up cap dry out problems
(1)
Specification
Model
ZMS100
(2) (4)
AC Input Voltage range
Input Fusing
-
85 - 264VAC (47-63Hz)
Line and neutral
Input Current (230V/115Vac)
Inrush Current - cold start
Harmonic Compliance
A
A
-
1.0 / 2.0
<40 (max at 264Vac input)
Compliant to EN/IEC61000-3-2 class A
Temperature Coefficient
-
<0.02% / °C
Hold Up Time at 80W load,115/230Vac ms
Hold Up Time at 100W load,115/230Vac ms
22 / 108 (see graphs for more detail)
16 / 84 (see graphs for more detail)
Leakage Current
µA
<100µA at 100V 60Hz input, <250µA at 230V 50Hz
Touch Current (enclosure leakage) µA
<100 µA
Cooling
Efficiency
-
-
80W with convection cooling, 100W max. with forced air cooling (see airflow rate graphs)
Up to 90% (see efficiency curves)
Operating Temperature
Storage Temperature
Operational Altitude
Overcurrent Protection
Overvoltage Protection
No Load Input Power at 230Vac
Average Active Efficiency
Humidity (non condensing)
Withstand Voltage
°C
°C
-
-20°C to +70°C, derate linearly to 50% load from 50°C to 70°C
-40°C to +85°C
5000m
hiccup (auto recovery)
Latching (unit shutdown, recycle mains to restart)
<0.5
W
%
RH
-
>87
Operating and storage : 5 - 95% (non-condensing)
Input to output 4kVac 2x MoPP, 1.5kVac input to ground 1x MoPP, 1.5kVac output to ground 1 x MoPP
>100MΩ at 25°C & 70%RH
Isolation Resistance
Ω
(3)
Isolation Class
Vibration
Shock
Construction suitable for Class II installations
10 to 500Hz at 2G, EN60068-2-6 19,6m/s² Constant, X, Y, Z 1 hour each.
30G EN60068-2-27, -47, MIL-STD-810E
IEC/EN/UL/CSA 62368-1, 60950-1 and 60601-1, ANSI/AAMI ES 60601-1,
CE and UKCA Marks. Designed to meet IEC/EN/UL/CSA 61010-1:2010. ZMS100-12,
15 and 24 are type tested to EN 60335-1.
EN 55011 / EN 55032 level B conducted, level A radiated
155
-
-
Approvals
-
(5)
Conducted & Radiated EMI
Weight (max)
Size (W x L x H)
Warranty
g
mm
yrs
50.8 x 101.6 x 31.9
3
Molex as standard with separate ground faston
Input Molex 10-63-4027, output Molex 09-65-2048
Connectivity
Notes: 1. Specification parameters apply at 25°C ambient temperature unless stated otherwise.
2. For 12V & 15V unit derate from 100% at 100V to 90% at 90V and to 80% at 85V, for 24V, 36V, & 48V unit derate from 100% at 90V to 90% at 85V. (convection and forced air ratings)
3. ZMS100 uses Y1 capacitors to earth.
.
4. Consult Sales Office for use under DC Input conditions.
5. Additional measures will be needed if used in environments where Class B radiated is required.
1