JMK, Inc
ZG-1435-5B
Operating Voltage = 125/250 Vac
Operating Current = 5.0 Ampere
Frequency of Operation = 60—400 Hz
A
A
Temperature Range (Storage) = -40 to 105 C
Temperature Range (Operating) = -40 to 65 C
Leakage current (Max) @ 125 V~, 60 Hz = 0.85 ma
Dielectric Withstand (L-Grd), (1 Minute) = 1500 Vac
Dielectric Withstand (L-L), (1 Minute) = 1500 Vdc
C
C
B
B
Order P/N: ZG-1435-5B for MIL-STD-461C
ZG-1435-5BD for MIL-STD-461D or E
The ZG-1435-5B filter has been designed for
systems operating under the requirements of
MIL-STD-461C. If MIL-STD-461D or E are specified
then part number ZG-1435-5BD should be specified.
The difference is that the differential capacitor is
repositioned on the line side in order to match the
test configuration of 461D and E.
80
70
60
50
40
30
20
10
0
CM
DM
The filter case is environmentally sealed and is
designed to handle the shock and vibration of
wheeled vehicle installations.
.1
.4
1
4
10
40
100
70
FREQUENCY (MEGAHERTZ)
400 1000
200 700
The circuit uses feed through capacitors the
insertion loss is 60 db to 1.0 Ghz and beyond.
.2
.7
2
7
20
0.63
3.00
MS3102R-10SL-3P
CARLINGSWITCH MODEL
MU2-B-94-450-1-C21-B-B
JMK Inc
ZG-1435-5B
125 Vac
60/ 400 Hz
5 amp, 60 C
3.00
0.750
0.90
0.43
1.50
0.75
C
A
1.50
0.719
B
0.719
4-40 X .25 DP INSERT (4 PL)
USA
JMK Inc 15 Caldwell Dr. Amherst, NH 03031 PH: 603 886-4100
email: info@jmkfilters.com
EUR JMK Inc Glasgow G13 1DN Scotland UK PH: 44-(0) 7785310729 FX: 44-(0) 141-589-1884
FX: 603 886-4115