APPLICABLE STANDARD
OPERATING
STORAGE
-40 C TO +125 C
-10 C TO +60 C (1)
RELATIVE HUMIDITY 85% MAX
(NOT DEWED)
TEMPERATURE RANGE
TEMPERATURE RANGE
1
RATING
60 V AC/DC
VOLTAGE
CURRENT
STORAGE
HUMIDITY RANGE
2
A
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
MARKING
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
×
×
×
×
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE
CONTACT RESISTANCE
MILLIVOLT LEVEL METHOD
INSULATION RESISTANCE
1A DC.
8 mΩ MAX .
8 mΩ MAX .
-
-
-
-
20 mV AC MAX, 0.1 mA(DC OR 1000Hz)
100 MΩMIN.
500V DC.
×
-
-
-
VOLTAGE PROOF
1000 V AC FOR 1 min.
NO BREAKDOWN.
1
MECHANICAL CHARACTERISTICS
MECHANICAL OPERATION
30 TIMES INSERTIONS AND EXTRACTIONS.
① CONTACT RESISTANCE: 16 m MAX.
-
×
-
-
-
-
②
NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
VIBRATION
FREQUENCY 20 TO 200Hz (88m/s2)
SWEEP TIME 3min.(ROUND TRIP)
AT 3h FOR 3 DIRECTIONS.
① NO ELECTRICAL DISCONTINUITY OF 7MIN,
1s MIN.
② CONTACT RESISTANCE: 16 m MAX.
-
×
-
-
-
-
③
NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
SHOCK
981m/s2 DURATION OF PULSE 6ms AT 3 TIMES
FOR 6 DIRECTIONS.
① NO ELECTRICAL DISCONTINUITY OF 7MIN,
1s MIN.
②
NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
×
×
-
-
LOCK STRENGTH
MEASURE BREAK STRENGTH OF THE LOCK BY 100N MIN.
PULLING THE CONNECTOR IN THE MATING
DIRECTION.
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
① CONTACT RESISTANCE: 16 m MAX.
② INSULATION RESISTANCE:100 M MIN.
EXPOSED AT 60 C, 90 ~ 95 %, 96 h.
-
×
×
-
×
-
-
-
-
-
(STEADY STATE)
③
NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
RAPID CHANGE OF
TEMPERATURE
① CONTACT RESISTANCE: 16 m MAX.
②
TEMPERATURE- 40 →ROOM TEMP →125C→
ROOM TEMP
NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
TIME
30 →
5 → 30 → 5 min
UNDER 1000 CYCLES.
DRY HEAT
EXPOSED AT 140C, 120 h.
① CONTACT RESISTANCE: 16 m MAX.
-
×
-
×
-
×
×
-
-
-
-
-
-
-
②
NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
COLD
EXPOSED AT -40C, 120 h.
① CONTACT RESISTANCE: 16 m MAX.
②
NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
RESISTANCE TO SO2 GAS
EXPOSED IN 25 PPM AT 75% MIN FOR 96h.
AFTER HEATING AT 120C FOR 120 h, WATER
AT 80C, 10 MPa, FOR 30 sec AT THE POSITIONS ② INSULATION RESISTANCE:100 M MIN.
OF ① TO ④.
CONTACT RESISTANCE: 16 m MAX.
➀ NO WATER PENETRATION PERMITTED.
RESISTANCE TO HIGH-
PRESSURE WASHING
1
ROTATE THE
MOUNTING
Nozzle
BASE AT 5 r/min.
Mounting base
Pivot
A point
COUNT
DESCRIPTION OF REVISIONS
DIS-T-00005917
DESIGNED
AN.SAIKI
CHECKED
DATE
1
△
3
HH.TSUKUMO
OM.MIYAMOTO
HH.TSUKUMO
AS.SHIBAHARA
MINTAE KANG
20200312
20190521
20190521
20190521
20190521
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
(NOTE1) "STORAGE" means a long-term storage state for the unused product.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-374260-00-00
PART NO.
CODE NO.
ZE064W-24DS-HU/R(B)
SPECIFICATION SHEET
1
△
1/1
HIROSE ELECTRIC CO., LTD.
CL753-2006-0-00
FORM HD0011-2-1