Specification for a Sinewave Output Thru-Hole
OCXO MtronPTI P/N: XO5085-061R
Electrical Specifications:
Parameter
Symbol
Min.
Typ.
Max.
Units
Conditions
Nominal Frequency
FO
100.0000
MHz
Frequency Stabilities
Over the Operating
Temperature Range
+/-250mV change in supply
voltage
vs. Temperature
-100
-30
+100
ppb
ppb
∆FT/F
vs. Supply voltage
variation
+30
Daily Aging
1 Year Aging
10-Years Aging
Retrace
-5
+5
ppb
ppm
ppm
ppb
-0.5
-2.0
-20
+0.5
+2.0
-20
After 30-days Power On
After 30-minutes power on
following 24-hours off
RF Output
Sinewave
+9
Output Type
Output Level
Output Load
+7.5
+10.5
dBm
Ω
50
±10%
Frequency Adjustment
Adjustment Method
Adjustment Voltage
Adjustment Range
Adjustment Slope
External Voltage
VTUNE
VDC
ppm
0
±0.5
+10
Over all conditions
Positive
Additional Parameters
-97
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
ppb/g
10Hz Offset
100Hz Offset
1kHz Offset
10kHz Offset
100kHz Offset
1MHz Offset
10MHz Offset
-128
-158
-170
-170
-170
-170
0.3
Phase Noise
(Under Static
Conditions)
G-sensitivity
Harmonics
Spurious
-25
-80
dBc
dBc
To within ±0.1ppm of the
frequency after 1-hour of
operation @ 25°C
Warm-up Time
5
minutes
Temperature, Supply Voltage & Power Consumption
Operating Temperature
OTR
-40
+85
°C
Full Specification
Compliance
Storage Temperature
Operating Voltage
STR
VCC
-55
+11.4
+85
+12.6
°C
VDC
+12.0
Steady state @ 25°C,
In Still Air
@ Warm-up
1.5
3.6
Watts
Watts
Power Consumption
1 of 2
The information contained herein is proprietary to MtronPTI and is submitted in confidence.
This information may not be copied or divulged without written permission from MtronPTI.