WRA_D-10W & WRB_D-10W Series
10W, 2:1 WIDE INPUT ISOLATED & REGULATED
DUAL/SINGLE OUTPUT DC-DC CONVERTER
multi-country patent protection RoHS
FEATURES
PRODUCT PROGRAM
Wide (2:1) Input Range
DIP package
Efficiency up to 86%
Input
Voltage (VDC)
Nominal Range
Output
Part
Number
Efficiency
(%, Typ)
Current (mA)
Voltage
(VDC)
Max*
Max
Min
±100
±42
±33
200
83
WRA0505D-10W
WRA0512D-10W
WRA0515D-10W
WRB0505D-10W
WRB0512D-10W
WRB0515D-10W
WRA1205D-10W
WRA1212D-10W
WRA1215D-10W
WRB1203D-10W
WRB1205D-10W
WRB1212D-10W
WRB1215D-10W
WRB1224D-10W
WRA2405D-10W
WRA2412D-10W
WRA2415D-10W
WRB2403D-10W
WRB2405D-10W
WRB2412D-10W
WRB2415D-10W
WRB2424D-10W
WRA4805D-10W
WRA4812D-10W
WRA4815D-10W
WRB4803D-10W
WRB4805D-10W
WRB4812D-10W
WRB4815D-10W
WRB4824D-10W
±5
±12
±15
5
±1000
±416
±333
2000
833
76
80
82
76
80
82
80
82
84
77
80
82
84
85
82
84
86
78
82
84
85
86
82
84
85
78
82
83
85
86
1.5KVDC Input/Output Isolation
Short Circuit Protection(automatic recovery)
Operating Temperature: -40°C to +85°C
Metal Shielding Package
No Heat Sink Required
Industry Standard Pinout
MTBF>1,000,000 hours
RoHS Compliance
5
4.5-9
11
12
15
666
66
±5
±1000
±416
±333
3030
2000
833
±100
±42
±33
300
200
83
±12
±15
3.3
5
12
9-18
20
40
80
12
15
666
66
24
416
42
APPLICATIONS
±5
±1000
±416
±333
3030
2000
833
±100
±42
±33
300
200
83
The WRA_D-10W & WRB_D-10W Series are
specially designed for applications where a wide
range input voltage power supplies are isolated
from the input power supply in a distributed power
supply system on a circuit board.
±12
±15
3.3
5
24
18-36
12
15
666
66
These products apply to:
24
416
42
1) Where the voltage of the input power supply is
wide range (voltage range≤2:1);
±5
±1000
±416
±333
3030
2000
833
±100
±42
±33
300
200
83
±12
±15
3.3
5
2) Where isolation is necessary between input
and output(Isolation Voltage ≤ 1500VDC);
3) Where the regulation of the output voltage and
the output ripple noise are demanded.
48
36-72
12
15
666
66
24
416
42
*Input voltage can’t exceed this value, or will cause the permanent damage.
Note: The load shouldn't be less than 10%, otherwise ripple will increase dramatically.
Operation under 10% load will not damage the converter; However, they may not meet all specification
listed.
MODEL SELECTION
OUTPUT SPECIFICATION
WRA0515D-10W
Item
Test conditions
Min
1
Typ
Max
10
Units
W
Rated Power
Package Style
Output Voltage
Output Power
See below products program
Positive Voltage Accuracy Refer to recommended circuit
Negative Voltage Accuracy Refer to recommended circuit
±1
±3
±3
Input Voltage
±5
Product Series
%
Load Regulation
From 10% To 100% load
±0.5
±0.2
±1*
±0.5
Line Regulation(at full load) Input voltage from low to high
Temperature Drift(Vout)
Ripple**
Refer to recommended circuit
20MHz bandwidth
±0.03 %/°C
20
85
50
mVp-p
150
Noise**
20MHz bandwidth
MORNSUN Science & Technology co.,Ltd.
Address: 2th floor 6th building, Huangzhou
Industrial District, Guangzhou, China
Tel: 86-20-38601850
Switching Frequency
*Dual output models unbalanced load: ±5%.
**Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of Power
Converter section, application notes.
100% load, Input voltage range
300
KHz
Fax:86-20-38601272
Note:
Http://www.mornsun-power.com
1. All specifications measured at TA=25°C, humidity<75%, nominal input voltage and rated output load unless
otherwise specified.
2. See below recommended circuits for more details.
MORNSUN reserves the copyright
Specifications subject to change without notice.
WRA_D-10W & WRB_D_10W
A/2-2008
Page 1 of 2