WMCUB6 SERIES
5-12 Watts
Rev C
AC/DC US Mini Charger
White Case (Suffix “W”)
Black Case (Suffix “B”)
Blue (Suffix “LB”)
FEATURES
• US Type AC Plug
• Small and Compact Size
• USB Type Outlet Connector • 90-264VAC Input Voltage Range
• RoHS Compliant
• REACH Compliant
• 10°C to +40° Operating
Temperature Range
• Over Current & Short Circuit
Protection
• UL and FCC Safety Approvals
• Several Case Colors Available
• 5-12 Watts Output Power
• 5 VDC Single Outputs
• Very Low Standby Power
• Level VI Compliant
Red Case (Suffix “R”)
Green (Suffix “G”)
DESCRIPTION
The WMCUB6 series of wall mount AC/DC power supplies delivers up
to 6 Watts of output power in a 1.39” x 1.63” x 0.75” package. This
series has single output models with an input voltage range of 90-
264VAC. These supplies are protected against over current and short
circuit conditions. The WMCUB6 series is RoHS, REACH, and Level VI
compliant and has UL and FCC safety approvals. These supplies are
also available in a variety of case colors.
Size: 1.39in x 1.63in x 0.91in (35.4mm x 41.5mm x 23mm)
MODEL SELECTION TABLE
Model Number(1)
WMCUB505-Ux
Input Voltage Range
90~264VAC
Output Voltage
Output Current
Ripple & Noise
100mVp-p
100mVp-p
100mVp-p
100mVp-p
Output Power
5W
5 VDC
1000mA
WMCUB1005-Ux
WMCUB10505-Ux
WMCUB1205-Ux
5 VDC
2000mA
10W
5 VDC
2100mA
10.5W
12W
5 VDC
2400mA
TECHNICAL SPECIFICATIONS: WMCUB6 SERIES
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
Min
Typ
Max
Unit
INPUT SPECIFICATIONS
Input Voltage
Input Frequency
Input Current
90
47
264
63
1.2
40
VAC
Hz
A
Inrush Current
A
Stand-by Power
OUTPUT SPECIFICATIONS
Output Voltage
At 230VAC/50Hz and no load
0.1
W
5
VDC
%
Line Regulation
1
Output Regulation
Output Power
-5
+5
12
%
W
Output Current
Ripple & Noise
See Table
100
mVp-p
mS
%/°C
Turn-on Time
Temperature Coefficient
PROTECTION
20-30
0.05
Over Current Protection
Short Circuit Protection
GENERAL SPECIFICATIONS
Efficiency
Automatic Recovery
Automatic Recovery
Energy Star VI
0.25
Insulation
Primary to Secondary
50
MΩ
mA
Leakage Current
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Storage Temperature
Humidity
10
-20
5
+40
+80
95
°C
°C
% RH
Non-condensing
Cooling
Convection
MTBF
0.5% annual field failure rate at 25°C
50,000
hours
Wall Industries, Inc. • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
website: www.wallindustries.com • e-mail: sales@wallindustries.com
7/29/2019
Page 1 of 3