描述
Dual Output Plug-in Signal Conditioners W-UNIT

WJV-H42-C 数据手册

 浏览型号WJV-H42-C的Datasheet PDF文件第2页浏览型号WJV-H42-C的Datasheet PDF文件第3页浏览型号WJV-H42-C的Datasheet PDF文件第4页 
MODEL: WJV  
(Minimum span 0.3 V,Input resistance 1 MΩ min.)  
Dual Output Plug-in Signal Conditioners W-UNIT  
[2] OUTPUT 1  
Current  
SIGNAL TRANSMITTER  
(field-programmable)  
A: 4 – 20 mA DC (Load resistance 600 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1200 Ω max.)  
C: 1 – 5 mA DC (Load resistance 2400 Ω max.)  
D: 0 – 20 mA DC (Load resistance 600 Ω max.)  
E: 0 – 16 mA DC (Load resistance 750 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1200 Ω max.)  
G: 0 – 1 mA DC (Load resistance 12 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
Functions & Features  
• Converting a DC input into a standard process signal  
• Micro-processor based  
• Field-programmable input range  
• Isolation up to 2000 V AC  
• Loop testing via hand-held programmer PU-2x  
• Highdensity mounting  
Typical Applications  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 1000 Ω min.)  
4: 0 – 10 V DC (Load resistance 10 kΩ min.)  
5: 0 – 5 V DC (Load resistance 5000 Ω min.)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)  
5W: -5 – +5 V DC (Load resistance 5000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
• Isolation between control room and field instrumentation  
• Ideal for quick spare part  
50  
(1.97)  
80  
(3.15)  
136  
(5.35)  
mm (inch)  
[3] OUTPUT 2  
Current  
A: 4 – 20 mA DC (Load resistance 350 Ω max.)  
B: 2 – 10 mA DC (Load resistance 700 Ω max.)  
C: 1 – 5 mA DC (Load resistance 1400 Ω max.)  
D: 0 – 20 mA DC (Load resistance 350 Ω max.)  
E: 0 – 16 mA DC(Load resistance 430 Ω max.)  
F: 0 – 10 mA DC (Load resistance 700 Ω max.)  
G: 0 – 1 mA DC (Load resistance 7000 Ω max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
MODEL: WJV–[1][2][3]–[4][5]  
ORDERING INFORMATION  
• Code number: WJV-[1][2][3]-[4][5]  
Specify a code from below for each of [1] through [5].  
(e.g. WJV-6AA-B/Q)  
• Special input and output ranges (For codes U1, U2, U3, Z  
& 0)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
Same range availability as Output 1  
Note: When the user requires a current and a voltage  
output, specify the current to be the Output 1 which allows  
a greater load.  
[4] POWER INPUT  
AC Power  
B: 100 V AC  
C: 110 V AC  
D: 115 V AC  
F: 120 V AC  
G: 200 V AC  
H: 220 V AC  
J: 240 V AC  
[1] INPUT  
Current  
A: 4 – 20 mA DC (Input resistance 250 Ω)  
H: 10 – 50 mA DC (Input resistance 100 Ω)  
Voltage  
6: 1 – 5 V DC (Input resistance 1 MΩ min.)  
U1: Range ±100 mV;  
DC Power  
S: 12 V DC  
(Minimum span 3 mV, Input resistance 20 kΩ min.)  
U2: Range ±1000 mV;  
R: 24 V DC  
V: 48 V DC  
(Minimum span 30 mV, Input resistance 20 kΩ min.)  
U3: Range ±10 V;  
WJV SPECIFICATIONS  
ES-2262 Rev.6 Page 1/4  
http://www.m-system.co.jp/  

与WJV-H42-C相关器件

型号 品牌 获取价格 描述 数据表
WJV-H42-C/Q MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WJV-H42-D MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WJV-H42-D/Q MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WJV-H42-J MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WJV-H42-J/Q MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WJV-H42-R MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WJV-H42-R/Q MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WJV-H42-S MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WJV-H42-S/Q MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WJV-H42-V MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT