Applicable standard
Operating
Storage
-40 °C to +105 °C( 90 %RH Max.)
-40 °C to +90 °C( 90 %RH Max.)
50 Ω( 0 to 8 GHz)
temperature range
temperature range
Characteristic
impedance
Applicable
cable
- W
-
Rating Power
0.81 Dia. coaxial cable.
Peculiarity
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
According to drawing.
QT AT
CONSTRUCTION
General examination
Visually and by measuring instrument.
X
X
ELECTRICAL CHARACTERISTICS
Insulation resistance
Withstanding voltage
Voltage standing
wave ratio
100 V DC.
500 MΩ Min.
X
X
X
X
200 V AC for 1 min. current leakage 2 mA Max.
Frequency 0 to 3 GHz.
Frequency 3 to 6 GHz.
No breakdown.
VSWR 1.3 Max.
VSWR 1.4 Max.
VSWR 1.5 Max.
1
X
-
Frequency 6 to 8 GHz.
MECHANICAL CHARACTERISTICS
Cable clamp strength
(Against cable pull)
Using a pulling tester, pull the cable axially at a rate
7 N Min.
of 10 mm/min. and record the strength at which
the cable or connector breaks.
X
-
Count
Description of revisions
Designed
MS.MATSUMOTO
Checked
Date
2
1
DIS-D-00011757
MT.KANEKO
20220510
Remark
HALOGEN FREE
VSWR is measured with SMA conversion adapters attached to
both ends of the applicable cable assembled.
TS.NOBE
20180619
Approved
Checked
Designed
Drawn
Notes
1
MT.KANEKO
20180619
20180619
20180619
2. “L” at the end of the product name indicates the cable length
(unit:mm).
3. Specifications are subject to change without notice.
MS.MATSUMOTO
MS.MATSUMOTO
2
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
Drawing No.
Part No.
SPECIFICATION SHEET
WFL2-LPHF6-04**TV-A-L
2
1/1
HIROSE ELECTRIC CO., LTD.
Code No.
FORM HD0011-2-1