Dual Output Plug-in Signal Conditioners W-UNIT

WAC-AB1A-B 数据手册

 浏览型号WAC-AB1A-B的Datasheet PDF文件第2页浏览型号WAC-AB1A-B的Datasheet PDF文件第3页 
MODEL: WAC  
A4: 0 – 5 V AC (Input resistance 100 kΩ min.)  
Dual Output Plug-in Signal Conditioners W-UNIT  
A5: 0 – 10 V AC (Input resistance 100 kΩ min.)  
A6: 0 – 120 V AC (Input resistance 100 kΩ min.)  
A7: 0 – 150 V AC (Input resistance 100 kΩ min.)  
A8: Specify voltage (See INPUT SPECIFICATIONS)  
(0 % input must be 0 V.)  
AC TRANSMITTER  
Functions & Features  
• Converting an alternating current/voltage into two  
standard process signals  
• True RMS sensing  
[2] OUTPUT 1  
Current  
• Isolation up to 2000 V AC  
• LCD meter  
A: 4 – 20 mA DC (Load resistance 600 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1200 Ω max.)  
C: 1 – 5 mA DC (Load resistance 2400 Ω max.)  
D: 0 – 20 mA DC (Load resistance 600 Ω max.)  
E: 0 – 16 mA DC (Load resistance 750 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1200 Ω max.)  
G: 0 – 1 mA DC (Load resistance 12 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
• High-density mounting  
Typical Applications  
• Converting a large AC current in combination with a shunt  
resistor, or a narrow span AC voltage  
50  
(1.97)  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 1000 Ω min.)  
4: 0 – 10 V DC (Load resistance 10 kΩ min.)  
5: 0 – 5 V DC (Load resistance 5000 Ω min.)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)  
5W: -5 – +5 V DC (Load resistance 5000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
80  
(3.15)  
136  
(5.35)  
mm (inch)  
MODEL: WAC–[1][2][3]–[4][5]  
ORDERING INFORMATION  
• Code number: WAC-[1][2][3]-[4][5]  
Specify a code from below for each of [1] through [5].  
(e.g. WAC-A1A6-B/E/Q)  
[3] OUTPUT 2  
Current  
A: 4 – 20 mA DC (Load resistance 350 Ω max.)  
B: 2 – 10 mA DC (Load resistance 700 Ω max.)  
C: 1 – 5 mA DC (Load resistance 1400 Ω max.)  
D: 0 – 20 mA DC (Load resistance 350 Ω max.)  
E: 0 – 16 mA DC(Load resistance 430 Ω max.)  
F: 0 – 10 mA DC (Load resistance 700 Ω max.)  
G: 0 – 1 mA DC (Load resistance 7000 Ω max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
• Special input and output ranges (For codes AZ, A8, Z & 0)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
Note: When the user requires a current and a voltage  
output, specify the current to be the Output 1 which allows  
a greater load.  
Same range availability as Output 1  
[1] INPUT  
Current  
AA: 0 – 10 mA AC (Input resistance 100 Ω)  
AB: 0 – 50 mA AC (Input resistance 20 Ω)  
AC: 0 – 100 mA AC (Input resistance 10 Ω)  
AD: 0 – 500 mA AC (Input resistance 1 Ω)  
AZ: Specify current (See INPUT SPECIFICATIONS)  
(0 % input must be 0 mA.)  
[4] POWER INPUT  
AC Power  
B: 100 V AC  
C: 110 V AC  
D: 115 V AC  
F: 120 V AC  
Voltage  
G: 200 V AC  
H: 220 V AC  
J: 240 V AC  
A1: 0 – 100 mV AC (Input resistance 100 kΩ min.)  
A2: 0 – 500 mV AC (Input resistance 100 kΩ min.)  
A3: 0 – 1 V AC (Input resistance 100 kΩ min.)  
DC Power  
WAC SPECIFICATIONS  
ES-2236 Rev.8 Page 1/3  
http://www.m-system.co.jp/  

与WAC-AB1A-B相关器件

型号 品牌 获取价格 描述 数据表
WAC-AB1A-B/Q MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WAC-AB1A-C MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WAC-AB1A-C/Q MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WAC-AB1A-D MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WAC-AB1A-D/Q MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WAC-AB1A-P MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WAC-AB1A-P/Q MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WAC-AB1A-R MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WAC-AB1A-R/Q MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WAC-AB1A-S MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT