VS-30CPU04-N3
Vishay Semiconductors
www.vishay.com
Ultrafast Rectifier, 2 x 15 A FRED Pt®
FEATURES
Common
cathode
• Ultrafast recovery time
• Low forward voltage drop
• 175 °C operating junction temperature
• Low leakage current
2, Base
1
• Designed and qualified according to
JEDEC®-JESD 47
2
3
1
3
• Material categorization: for definitions of compliance
please see www.vishay.com/doc?99912
TO-247AC 3L
Anode
1
Anode
2
DESCRIPTION / APPLICATIONS
FRED Pt® series are the state of the art ultrafast recovery
rectifiers specifically designed with optimized performance
of forward voltage drop and ultrafast recovery time.
The planar structure and the platinum doped life time
control, guarantee the best overall performance,
ruggedness and reliability characteristics.
These devices are intended for use in the output rectification
stage of SMPS, UPS, DC/DC converters as well
as freewheeling diodes in low voltage inverters and chopper
motor drives.
PRIMARY CHARACTERISTICS
IF(AV)
2 x 15 A
VR
400 V
VF at IF
0.93 V
t
rr typ.
See Recovery table
175 °C
TJ max.
Package
TO-247AC 3L
Common cathode
Circuit configuration
Their extremely optimized stored charge and low recovery
current minimize the switching losses and reduce over
dissipation in the switching element and snubbers.
ABSOLUTE MAXIMUM RATINGS
PARAMETER
SYMBOL
TEST CONDITIONS
VALUES
UNITS
Peak repetitive reverse voltage
VRRM
400
V
per leg
Average rectified forward current
total device
15
30
IF(AV)
Rated VR, TC = 149 °C
A
Non-repetitive peak surge current per leg
Peak repetitive forward current per leg
Operating junction and storage temperatures
IFSM
IFRM
TC = 25 °C, tp = 10 ms
200
Rated VR, TC = 149 °C, square wave, 20 kHz
30
TJ, TStg
-65 to +175
°C
ELECTRICAL SPECIFICATIONS (TJ = 25 °C unless otherwise specified)
PARAMETER
SYMBOL
TEST CONDITIONS
MIN.
TYP.
MAX.
UNITS
Breakdown voltage,
blocking voltage
VBR
VR
,
IR = 100 μA
IF = 15 A
400
-
-
V
-
-
-
-
-
-
1.17
0.93
0.3
30
1.25
1.12
10
Forward voltage
VF
IR
IF = 15 A, TJ = 150 °C
VR = VR rated
Reverse leakage current
μA
TJ = 150 °C, VR = VR rated
VR = 400 V
500
-
Junction capacitance
Series inductance
CT
LS
28
pF
nH
Measured lead to lead 5 mm from package body
12
-
Revision: 25-May-2020
Document Number: 94013
1
For technical questions within your region: DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000