VRE117/118/119
Precision
Reference Supplies
THALER CORPORATION • 2015 N. FORBES BOULEVARD • TUCSON, AZ. 85745 • (520) 882-4000
FEATURES
APPLICATIONS
• PRECISION A/D and D/A CONVERTERS
• TRANSDUCER EXCITATION
• VERY HIGH ACCURACY: 3.000 V OUTPUT ±200 µV
• EXTREMELY LOW DRIFT: 0.6 ppm/°C 55°C to +125°C
• LOW WARM-UP DRIFT: 1 ppm Typ.
• ACCURATE COMPARATOR THRESHOLD
REFERENCE
• EXCELLENT STABILITY: 6 ppm/1000 Hrs. Typ.
• EXCELLENT LINE REGULATION: 3 ppm/V Typ.
• HERMETIC 14-PIN CERAMIC DIP
• HIGH RESOLUTION SERVO SYSTEMS
• DIGITAL VOLTMETERS
• HIGH PRECISION TEST and
MEASUREMENT INSTRUMENTS
• MILITARY PROCESSING OPTION
DESCRIPTION
VRE117 Series Precision Voltage References
provide ultrastable +3.000V (VRE117), -3.000V
(VRE118) and ±3.000V (VRE119) outputs with
±0.200 mV initial accuracy and temperature
coefficient as low as 0.6 ppm/°C over the full
SELECTION GUIDE
Temperature
Operating Range
Max. Volt
Deviation
Type
Output
VRE117C
VRE117CA +3.0V -25°C to +85°C
VRE117M +3.0V -55°C to +125°C
VRE117MA +3.0V -55°C to +125°C
VRE118C -3.0V -25°C to +85°C
VRE118CA -3.0V -25°C to +85°C
VRE118M -3.0V -55°C to +125°C
VRE118MA -3.0V -55°C to +125°C
VRE119C ±3.0V -25°C to +85°C
VRE119CA ±3.0V -25°C to +85°C
VRE119M ±3.0V -55°C to +125°C
VRE119MA ±3.0V -55°C to +125°C
+3.0V -25°C to +85°C
200 µV
100 µV
400 µV
200 µV
military temperature range. This improvement in
accuracy is made possible by unique,
proprietary multipoint laser compensation
a
technique developed by Thaler Corporation.
Significant improvements have been made in
other performance parameters as well, including
initial accuracy, warm-up drift, line regulation, and
long-term stability, making the VRE117 series the
most accurate and stable 3.0V reference
available.
200 µV
100 µV
400 µV
200 µV
200 µV
100 µV
400 µV
200 µV
VRE117/118/119 devices are available in two
operating temperature ranges, -25°C to +85°C
and -55°C to +125°C, and two performance
grades. All devices are packaged in 14-pin hermetic ceramic packages for maximum long-term stability. "M"
versions are screened for high reliability and quality.
Superior stability, accuracy, and quality make these references ideal for precision applications such as A/D
and D/A converters, high-accuracy test and measurement instrumentation, and transducer excitation.
VRE117DS REV. C NOV 2000