DC/DC Converter
VRA_ZP-6WR2 & VRB_ZP-6WR2 Series
6W, wide input voltage, isolated & regulated output
DC/DC converter
FEATURES
Wide range of input voltage (2:1)
Efficiency up to 89%
Isolation voltage: 1.5K VDC
Output over-voltage protection,
short-circuit protection
Operating temperature range: -40℃ to +85℃
Low ripple & noise
Meet CISPR22/EN55022 CLASS A
International standard pin-out
Meet EN60950
Patent Protection RoHS
VRA_ZP-6WR2 & VRB_ZP-6WR2 series are isolated 6W DC-DC products with 2:1 input voltage . They feature efficiency up to 89%, 1500VDC
isolation, operating temperature of -40 ℃ ~+85 ℃ , output over-voltage protection , short-circuit protection and EMI meets
CISPR22/EN55022 CLASS A, which make them widely applied in industrial control, electricity, instruments, communication fields.
Selection Guide
Input Voltage (VDC)
Output
Efficiency
(%,Min./Typ.)
@ Full Load
Max. Capacitive
①
③
Certification
Part No.
Nominal
(Range)
Output Voltage Output Current (mA)
④
②
Load (µF)
Max.
(Max./Min.)
±600/±30
±250/±12
±200/±10
1500/75
1200/60
500/25
(VDC)
VRA1205ZP-6WR2
VRA1212ZP-6WR2
VRA1215ZP-6WR2
VRB1203ZP-6WR2
VRB1205ZP-6WR2
VRB1212ZP-6WR2
VRB1215ZP-6WR2
VRB1224ZP-6WR2
VRA2405ZP-6WR2
VRA2409ZP-6WR2
VRA2412ZP-6WR2
VRA2415ZP-6WR2
VRA2418ZP-6WR2
VRA2424ZP-6WR2
VRB2403ZP-6WR2
VRB2405ZP-6WR2
VRB2409ZP-6WR2
VRB2412ZP-6WR2
VRB2415ZP-6WR2
VRB2424ZP-6WR2
VRA4805ZP-6WR2
VRA4812ZP-6WR2
VRA4815ZP-6WR2
VRB4803ZP-6WR2
VRB4805ZP-6WR2
VRB4812ZP-6WR2
VRB4815ZP-6WR2
±5
79/81
83/85
83/85
74/76
79/81
83/85
83/85
85/87
81/83
84/86
85/87
85/87
84/86
86/88
77/79
81/83
83/85
85/87
87/89
86/88
81/83
85/87
86/88
77/79
81/83
86/88
86/88
470
100
100
1800
1000
100
100
47
--
±12
±15
3.3
5
12
20
(9-18)
CE
12
15
400/20
24
250/12
±5
±9
±12
±15
±18
±24
3.3
5
±600/±30
±333/±16
±250/±12
±200/±10
±166/±8
±125/±6
1500/75
1200/60
667/33
470
100
100
100
150
47
--
CE
--
CE
--
24
40
(18-36)
1800
1000
470
100
100
47
9
12
500/25
15
400/20
24
250/13
±5
±12
±15
3.3
5
±600/±30
±250/±12
±200/±10
1500/75
1200/60
500/25
470
100
100
1800
1000
100
100
48
80
(36-75)
CE
12
15
400/20
Notes:
①Exceeding the maximum input voltage may cause permanent damage;
②For the dual output modules, the capacitive loads of positive and negative outputs are the same.
2015.09.11-A/4
Page 1 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation