PART NUMBER: VPLN-60 Series
DESCRIPTION: switching power supply
features
·universal AC input / full range
·fully isolated plastic case with IP64 level
·built-in constant current limiting circuit with adjustable OCP level
·protections: short circuit/over load/over voltage/over temperature
·built-in active PFC function
·IP64 design for indoor or outdoor installations
·UL1310, Class 2 power unit
·100% full load burn-in test
·cooling by free air convection
·suitable for LED lighting and moving sign applications
·high realibility
·2 year warranty
Model
VPLN-60-12
VPLN-60-15
VPLN60-20
VPLN-60-24
VPLN-60-27
VPLN-60-36 VPLN-60-48
DC output voltage
12V
15V
20V
24V
27V
36V
48V
3
Vout tolerance
±10%
5A
±10%
4A
±10%
3A
±10%
2.5A
±10%
2.3A
±10%
1.7A
±10%
1.3A
output rated current
output min. range
output max. range
peak load
0A
0A
0A
0A
0A
0A
0A
5A
4A
3A
2.5A
2.3A
1.7A
1.3A
60W
60W
60W
60W
62.1W
2.7Vp-p
±4.0%
±10%
87%
61W
62.5W
4.6Vp-p
±4.0%
±10%
88%
2
ripple & noise
2Vp-p
±4.0%
±10%
83%
2.4Vp-p
±4.0%
±10%
84.5%
13.8~16.2V
1.8Vp-p
±4.0%
±10%
86.5%
18~22V
2.7Vp-p
±4.0%
±10%
86.5%
22~26V
3.6Vp-p
±4.0%
±10%
87%
line regulation
3
load regulation
efficiency
6
DC voltage adj.
11~13V
90~264VAC
47~63 Hz
3%~-25%
25~30V
32.5~39V
43.6~51.8V
5
input voltage range
frequency range
6
current adj. range
AC input current
inrush current
0.8A/115VAC; 0.4A/230VAC
40A/230VAC
leakage current
0.5mA/240VAC
overload protection
shortcircuit protection
95%-110% 130% (max) type: constant current limiting, recovers automatically after fault removal
hiccup mode, recovers automatically after fault condition is removed
4
over voltage protection
13.8~16V
17.5~21V
22.8~25V
28~32V
31~35V
41~46V
54~60V
type: shut down o/p voltage, recovers automatically after temperature goes down
over temp. protection
95°C ±10°C (TSW1) detect on heatsink of power transistor type: shutdown o/p voltage, recovers
automatically after fault removal
temperature coefficient
set up, rise, hold up time
vibration
±0.03% / °C (0~50°C)
1500ms, 100ms / 230VAC, 300ms, 100ms / 115VAC at full load
10~500Hz, 2G 10min./1 cycle (1 hour each axes)
withstand voltage
isolation resistance
working temp., humidity
storage temp., humidity
MTBF
I/P-O/P: 4.25KVAC,
I/P-O/P, 500VDC / 100M Ohms min.
-30°C~+50°C (refer to output derating curve), 20%-90% RH
-40°C~+80°C, 10-95% RH
497.8Khrs/min at full load 25°C MIL-HDBK-217F
safety standards
EMC standards
UL1310 Class 2,CAN/CSA C22.2 NO. 223-M91(except for 48V), EN61347-1, EN61347-2-13, IP64 Approved
CISPR11 (EN55011), CISPR22 (EN55022) class B, EN61000-3-2,3, EN61000-4,2,3,4,5,6,8,11,
ENV50204, EN55024, EN61547 (light industrial level, criteria A)
Notes:
1. all parameters NOT specifically mentioned are measured at 230Vac input, rated load, 25°C ambient
2. ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a 0.1μF & 47 μF capacitor
3. tolerance includes set up tolerance, line regulation, load regulation
4. please refer to OLP characteristics.
5. derating may be needed under low input voltage. Please check the derating curve for more details
6. output voltage can be adjusted through the SVR1 on the PCB; limit of output constant current level can be adjusted through the SVR2 on the PCB
th