FlatPAC™
50 to 600 Watts Autoranging, AC-DC Switchers
Features & Benefits
Configuration Chart
0
1
1
E U U U
-
Typical Model: VI-RU
-
• RoHS compliant (VE versions)
• Microcontroller architecture
• Inputs: 115/230 Vac autoranging
Input
115/230 Vac
Output
Input Characteristics
90–132/180–264 Vac
U = Autoranging
1: 5 VDC at 200W
2: 12 VDC at 200W
3: 12 VDC at 200W
• Meets FCC Part 15, EN55022,
Class B conducted emissions
• 80 – 90% efficiency
Substitute VE– for VI– for RoHS compliant versions
Total Power # of Converters
• Any output: 1 to 95VDC
Configuration
Single Output
Dimensions
• Module enable/disable
(except LU series)
9.25” x 2.5” x 1.37”
(234,8 x 124,5 x 34,8mm)
9.25” x 4.9” x 1.37”
(234,8 x 124,5 x 34,8mm)
9.25” x 7.3” x 1.37”
(234,8 x 185,4 x 34,8mm)
VI-LU
VI-MU
VI-NU
-
50 – 200W
200 – 400W
300 – 600W
1
2
3
• UL, TÜV, CE marked
• Remote sense and current limit
-
• BUS OK and AC OK
(except LU series)
-
• 40ms ride-through time
• OVP and thermal shutdown
• 1 output; up to 200W
Dual Output
9.25” x 4.9” x 1.37”
VI-PU
-
100 – 400W
150 – 600W
2
3
(234,8 x 124,5 x 34,8mm)
9.25” x 7.3” x 1.37”
(234,8 x 185,4 x 34,8mm)
• 1 or 2 outputs; up to 400W
VI-QU
-
• 1, 2, or 3 outputs; up to 600W
Triple Output
9.25” x 7.3” 1.37”
(234,8 x 185,4 x 34,8mm)
Product Highlights
VI-RU
-
150 – 600W
3
If you’re looking for the convenience of a complete,
low-profile, agency-approved switching power supply,
look no further. The FlatPAC combines the Vicor
workhorse VI-200 family of DC-DC converters with
a modular package and front-end subassembly to
provide from 50 to 600W of output power from one
to three outputs.
Output Voltage
Z = 2V
W = 5.5V
M = 10V
1 = 12V
P = 13.8V
2 = 15V
N = 18.5V
3 = 24V
L = 28V
J = 36V
K = 40V
4 = 48V
H = 52V
F = 72V
D = 85V
B = 95V
Y = 3.3V
0 = 5V
V = 5.8V
T = 6.5V
R = 7.5V
X = 5.2V
A flat plate heat sink for use in conduction cooled
applications may be specified as an alternate to the
standard finned version by adding “CC” to the end of
the model number.
Product Grade Temps. °C
Output Power/Current
Grade
Operating
Storage
VOUT ≥5V
VOUT < 5V
E =
C =
=
0 to +85
0 to +85
–30 to +85
–20 to +100
–20 to +100
–55 to +100
Y
X
= 50W
= 75W
Y
X
= 10A
= 15A
The Vicor FlatPAC is also available with a current
controlled output using BatMod converter modules
of 12, 24, or 48VDC outputs. This option is specified
by appending “BM” or “BC” (for conduction cooled
versions) to the end of the FlatPAC model number.
W = 100W
W = 20A
I
V
U
= 150W
= 200W
V
U
= 30A
= 40A
Temperatures apply to product case.
Output Power/Current
Output Power/Current
VOUT ≥5V
VOUT < 5V
Mixing VI-200 and BatMods in a single FlatPAC is
not permissible.
VOUT ≥5V
VOUT < 5V
W= 100W
V = 150W
U = 200W
S = 300W
Q = 400W
W= 20A
V = 30A
U = 40A
S = 60A
Q = 80A
S = 300W
P = 450W
M = 600W
S = 60A
P = 90A
M = 120A
The FlatPAC’s contemporary design allows us to
configure your order quickly and provide rapid
turnaround on standard models. It is truly a complete
power solution, enabling you to spend more time
designing your system and less time worrying about
how to power it.
Options
BC = BatMod/Conduction Cooled
BM = BatMod
CC = Conduction Cooled
Note: Product images may not highlight current product markings.
FlatPAC™
Page 1 of 6
Rev 1.8
11/2021