VBO 25
IdAV = 38 A
VRRM = 800-1600 V
Single Phase
Rectifier Bridge
Standard and Avalanche Types
~
+
VRSM VBRmin
①
VRRM
V
Standard
Types
Avalanche
Types
–
V
V
~
~
900
800
VBO 25-08NO2
1300 1230
1500 1430
1700 1630
1200 VBO 25-12NO2 VBO 25-12AO2
1400 VBO 25-14NO2 VBO 25-14AO2
1600 VBO 25-16NO2 VBO 25-16AO2
+
–
~
① For Avalanche Types only
Symbol
Test Conditions
Maximum Ratings
Features
• Avalanche rated parts available
• Package with DCB ceramic base plate
• Isolation voltage 3600 V~
• Planar passivated chips
• Low forward voltage drop
• ¼" fast-on terminals
IdAV
IdAVM
PRSM
②
TC = 85°C, module
38
40
3.4
A
A
kW
module
TVJ = TVJM
t = 10 µs
IFSM
TVJ = 45°C;
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
370
390
A
A
T
VJ = TVJM
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
320
340
A
A
• UL registered E 72873
VR = 0
I2t
TVJ = 45°C
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
680
640
A2s
A2s
A2s
A2s
Applications
VR = 0
• Supplies for DC power equipment
• Input rectifiers for PWM inverter
• Battery DC power supplies
TVJ = TVJM
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
510
470
• Field supply for DC motors
TVJ
TVJM
Tstg
-40...+150
150
-40...+125
°C
°C
°C
Advantages
• Easy to mount with one screw
• Space and weight savings
• Improvedtemperatureandpowercycling
VISOL
50/60 Hz, RMS t = 1 min
IISOL ≤ 1 mA t = 1 s
3000
3600
V~
V~
Md
Mounting torque (M5)
(10-32 UNF)
typ.
1.5-2
13-18 lb.in.
15
Nm
Dimensions in mm (1 mm = 0.0394")
Weight
g
Symbol
IR
Test Conditions
Characteristic Values
VR = VRRM
VR = VRRM
;
;
TVJ = 25°C
TVJ = TVJM
≤
≤
0.3 mA
5
mA
VF
IF = 55 A;
TVJ = 25°C
≤
1.36
V
VT0
rT
For power-loss calculations only
TVJ = TVJM
0.85
8
V
mΩ
RthJC
per diode, DC current
per module
per diode, DC current
per module
2.8 K/W
0.7 K/W
3.2 K/W
0.8 K/W
RthJK
dS
dA
a
Creeping distance on surface
Creepage distance in air ③
Max. allowable acceleration
13 mm
9.5 mm
50 m/s2
Data according to IEC 60747 and refer to a single diode unless otherwise stated
for resistive load at bridge output, ③ with isolated fast-on tabs.
②
IXYS reserves the right to change limits, test conditions and dimensions.
© 2004 IXYS All rights reserved
1 - 2