USD7185A - PRELIMINARY
Band 71 (with B85 UL) USD Series Duplexer
Features
▪ Low Loss with High Rejection
▪ Superior power handling and reliability
▪ Universal footprint across all FDD frequency bands
Applications
ESTIMATE
▪ Wireless Infrastructure applications
Part Dimensions: 63.0 × 16.4 × 10.5 mm • 40.5 g
Materials: Ag plated ceramic block with tin plated brass shield
▪ High-performance carrier-grade small-cells using linearized
PA for 1.0-2.0W at the antenna port.
▪ Wide-band pico-cells or small-cells requiring multi-channel or carrier aggregation.
Description
Surface mount ceramic duplexer supports a universal footprint across all FDD frequency bands enabling the use of
a common system PCB. Provides superior rejection, insertion loss, reliability, as well as both peak and average
power handling compared to other duplexer technologies.
Electrical Specifications
Frequency
Typical
Spec.
Spec. over
Parameter
(MHz)
at 25⁰C
at 25⁰C
-40⁰C to +85⁰C
Nominal Impedance
Average Input Power
Peak Input Power
-
-
-
50 ohms
-
-
-
-
-
-
6.0 Watt max
60 Watt max
Antenna to UL Response
Passband Insertion Loss (5 MHz avg)
Passband Insertion Loss (single-point)
Passband Ripple
663 - 716
663 - 716
663 - 716
663 - 716
617 - 652
729 - 800
2.7 dB max
3.5 dB max
2.8 dB max
11 dB min
64 dB min
35 dB min
2.9 dB max
4.0 dB max
3.3 dB max
11 dB min
64 dB min
35 dB min
Passband Return Loss
13 dB
65 dB
37 dB
Attenuation:
DL to Antenna Response
Passband Insertion Loss (5 MHz avg)
Passband Insertion Loss (single-point)
Passband Ripple
617 - 652
617 - 652
617 - 652
617 - 652
663 - 716
2.7 dB max
3.5 dB max
2.8 dB max
11 dB min
66 dB min
2.9 dB max
4.0 dB max
3.3 dB max
11 dB min
66 dB min
Passband Return Loss
13 dB
67 dB
Attenuation:
DL to UL Response
Attenuation for UL band
Attenuation for transition band
Attenuation for DL band
663 - 716
653 - 662
617 - 652
70 dB
45 dB
66 dB
69 dB min
40 dB min
65 dB min
69 dB min
40 dB min
65 dB min
Note: CTS tests each unit to the critical specifications above.
Subsequent audits may deviate due to repeatability among
different test systems which shall not exceed these allowances.
Specification Allowance
Insertion Loss
Return Loss
Attenuation
0.1 dB
1.0 dB
1.0 dB
2021-02-08 Rev. B
Page 1 of 3
©2016 CTS® Corporation. Information/product(s) subject to change. No warranty that product(s) will meet the stated specifications for customer specific applications or test