DC/DC Converter
URF_LP-10WR3 Series
10W,Ultra wide input isolated & regulated
DC-DC converter
FEATURES
Wide range of input voltage (4:1)
Efficiency up to 87%
No-load power consumption as low as 0.12W
Isolation voltage :3K VDC
Input
under-voltage
protection,
output
over-voltage protection, short circuit protection,
output over-current protection
Operating temperature range: -40℃ to +85℃
Meet CISPR22/EN55022 CLASS A
A2S (wring mounting) and A4S (TS35 rail mounting)
products featuring anti-reverse connection for
input
IEC60950, UL60950, EN60950 Approval
International standard pin-out
CB
Patent Protection RoHS
URF_LP-10WR3 series are isolated 10W DC-DC products with 4:1 input voltage. They feature efficiency up to 87%, 1500VDC isolation,
operating temperature of -40 ℃ ~+85 ℃ , Input under-voltage protection, output short circuit protection, over-voltage protection,
over-current protection and EMI meets CISPR22/EN55022 CLASS A, which make them widely applied in industrial control, electric power,
instruments and communication fields. And extension package A2S and A4S also enable them with reverse voltage protection.
Selection Guide
Input Voltage (VDC)
Output
Output Current (mA)
Efficiency
(%,Typ.)
Max. Capacitive
Load(µF)
①
③
Part No.
Certification
Nominal
(Range)
Output Voltage
(VDC)
②
Max.
@ Full Load
77/79
80/82
83/85
84/86
85/87
85/87
77/79
80/82
84/86
85/87
85/87
(Max./Min.)
2400/0
2000/0
1111/0
833/0
URF2403LP-10WR3
URF2405LP-10WR3
URF2409LP-10WR3
URF2412LP-10WR3
URF2415LP-10WR3
URF2424LP-10WR3
URF4803LP-10WR3
URF4805LP-10WR3
URF4812LP-10WR3
URF4815LP-10WR3
URF4824LP-10WR3
3.3
5
5400
5400
680
9
24
40
(9-36)
12
15
24
3.3
5
470
667/0
330
UL/CE/CB
416/0
100
2400/0
2000/0
833/0
5400
5400
470
48
80
12
15
24
(18-75)
667/0
330
416/0
100
Notes:
①Part No. with suffix of “A2S” means chassis mounting and suffix of “A4S” means DIN-Rail mounting (e.g. URF2405LP-10WR3A2S means chassis mounting;
URF2405LP-10WR3A4S means DIN-Rail mounting);
②Absolute maximum rating without damage on the converter, but it isn't recommended;
③Efficiency is measured In nominal input voltage and rated output load;A2S (wiring) and A4S (rail) Model due to input reverse polarity protection, minimum
efficiency greater than Min.-2 is qualified.
Input Specifications
Item
Operating Conditions
24VDC input
Min.
--
Typ.
508/5
254/4
40
Max.
521/12
261/12
--
Unit
mA
Input Current (full load / no-load)
48VDC input
--
24VDC input
--
Reflected Ripple Current
Input impulse Voltage (1sec. max.)
Starting Voltage
48VDC input
--
30
--
24VDC input
-0.7
-0.7
--
--
50
48VDC input
--
100
9
VDC
24VDC input
--
48VDC input
--
--
18
2015.08.12-A/2