DC/DC Converter
URF1D_LD-40WR3 Series
40W, Ultra wide input, isolated & regulated single output
DC/DC converter
FEATURES
Ultra wide input voltage range (4:1)
Enhanced isolation, isolation voltage:
3.0KVDC/1.5KVAC
Operating temperature range: -40℃ to +85℃
Input Under-voltage Protection, Output short
circuit, over-current, over–voltage protection,
over-temperature protection
Meets requirements of railway standard
EN50155
Reverse voltage protection available with
A2S(Chassis mounting) or A4S(35mm DIN-Rail
mounting)
International standard pin-out
Patent Protection RoHS
URF1D_LD-40WR3 series are isolated 40W DC-DC products with 4:1 input voltage .Their feature efficiency up to 91%, 1500VAC / 3000VDC
isolation with enhanced isolation, operating temperature of -40℃ to +85℃, Input Under-voltage Protection, Output short circuit,
over-current, over–voltage, over- temperature protectionprotection.Railway vehicle electronic equipment widely used in 72V, 96V and
110V.
Selection Guide
④
Input Voltage (VDC)
Output
Efficiency
(%,Min./Typ.)
@ Full Load
Max. Capacitive
Load(µF)
①
②
Part No.
Certification
Nominal
(Range)
Output Voltage
(VDC)
Output Current
③
Max.
(mA)(Max./Min.)
10000/0
8000/0
URF1D03LD-40WR3
URF1D05LD-40WR3
URF1D12LD-40WR3
URF1D15LD-40WR3
URF1D24LD-40WR3
URF1D48LD-40WR3
3.3
5
85/87
86/88
89/91
89/91
87/89
87/89
10000
10000
2700
1680
680
12
15
24
48
3333/0
110
170
--
(40-160)
2667/0
1667/0
833/0
470
Note:
①Series with suffix “H” are heat sink mounting; series with suffix “A2S” are chassis mounting,with suffix “A4S” are DIN-Rail mounting, for example
URF1D05LD-40WHR3A2S is chassis mounting of with heat sink, URF1D05LD-40WR3A4S is DIN-Rail mounting of without heat sink; If the application has a higher
requirement for heat dissipation, you can choose modules with heat sink;
②The minimum input voltage and starting voltage of A2S (wiring) and A4S (rail) Model are 1VDC higher than those of DIP package due to input reverse polarity
protection function;
③Absolute maximum rating without damage on the converter, but it isn't recommended;
④Efficiency is measured In nominal input voltage and rated output load;A2S (wiring) and A4S (rail) Model due to input reverse polarity protection, minimum
efficiency greater than Min.-2 is qualified.
Input Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Unit
mA
3.3V output
Others
--
--
345/5
413/3
25
353/15
Input Current (full load / no-load) Nominal input voltage
423/15
Reflected Ripple Current
Surge Voltage (1sec. max.)
Starting Voltage
Shutdown Voltage
Starting Time
Nominal input voltage
100% load
--
--
180
40
--
-0.7
--
--
VDC
ms
--
28
--
32
Nominal input voltage & constant resistance load
20
--
Input Filter
Pi filter
Hot Plug
Unavailable
2018.05.04-A/0
Page 1 of 8