DC/DC Converter
URF1D_QB-50W Series
50W, wide input voltage,
isolated & regulated single output DC-DC converter
FEATURES
Wide input voltage range: 66-160VDC
High efficiency up to 90%
Low no-load power consumption
Isolation voltage:3K VDC
Operating temperature range: -40℃ to +100℃
Input under-voltage protection, output
over-voltage, over-current, short-circuit,
over-temperature protection
Patent Protection RoHS
International standard: 1/4 brick
Meets requirements of railway standard
EN50155
URF1D_QB -50W Series is a high performance product designed for the field of railway applications. The DC/DC converters feature 50W
output power, no min. load requirement, wide input voltage of 66-160VDC, And allow the high base plate temperature(up to 100℃). The
products also provide input under-voltage protection, output over-voltage protection, short-circuit protection, over-temperature
protection, remote control and compensation, output voltage regulation functions. The series meet railway standard EN50155 . And target
railway system.
Selection Guide
Input Voltage (VDC)
Nominal
(Range)
Output
Output Current
Efficiency
(%, Min./Typ.)
@ Full Load
Max. Capacitive
Load(µF)
①
Part No.
Output
Voltage(VDC)
②
Max.
(mA)(Max./Min.)
URF1D03QB-50W
URF1D03QB-50WH
URF1D05QB-50W
3.3
5
15000/0
84/86
86/88
10000
7500
10000/0
URF1D05QB-50WH
URF1D12QB-50W
URF1D12QB-50WH
URF1D15QB-50W
URF1D15QB-50WH
URF1D24QB-50W
URF1D24QB-50WH
110
(66-160)
170
12
15
24
4167/0
3333/0
2083/0
86/88
86/88
88/90
6000
4700
3000
Note: ①Series with suffix “H” are heat sink mounting, for example URF1D05QB-50WH is chassis mounting of with heat sink;
②Exceeding the maximum input voltage may cause permanent damage.
Input Specifications
Item
Operating Conditions
URF1D03QB-50W(H)
Min.
--
Typ.
523/5
516/5
516/5
516/5
505/5
50
Max.
Unit
mA
536/15
528/15
528/15
528/15
516/15
--
URF1D05QB-50W(H)
URF1D12QB-50W(H)
URF1D15QB-50W(H)
URF1D24QB-50W(H)
--
Nominal input
voltage
Input Current (full load / no-load)
--
--
--
Reflected Ripple Current
Surge Voltage (1sec. max.)
Starting Voltage
Nominal input voltage
--
-0.7
--
--
180
--
66
VDC
ms
Input Under-voltage Protection
Starting Time
--
58
--
--
25
--
Input Filter
Pi filter
Unavailable
Hot Plug
Module switch on
Ctrl open circuit or connected to TTL high level (3.5-12VDC)
Ctrl connected to -Vin or low level (0-1.2VDC)
Module switch off
Ctrl*
Input current when switched off
mA
--
2
--
Note: * the voltage of Ctrl pin is relative to input pin -Vin.
2017.07.19-A/4
Page 1 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation