DC/DC Converter
URE1D_LD-20WR3 Series
20W, Ultra wide input, isolated & regulated Dual output,
DC/DC converter
FEATURES
Ultra wide input voltage range (4:1)
Enhanced isolation, Isolation voltage: 3K VDC &
1.5K VAC
Operating temperature range: -40℃ to +85℃
Input Under-voltage Protection, Output short
circuit, over-current, over–voltage protection
Low ripple & noise
Meet EN50121-3-2 CISPR32/EN55032 CLASS A,
without external components
Meets requirements of railway standard EN50155
Reverse voltage protection available with
A2S(Chassis mounting) or A4S(35mm DIN-Rail
mounting)
Meets IEC60950, UL60950, EN60950 standards
Meets requirements of railway standard EN50155
International standard pin-out
Patent Protection RoHS
URE1D_LD-20WR3 series are isolated 20W DC-DC products with 4:1 input voltage .Their feature efficiency up to 86%, 3000VDC &1500VAC
isolation with enhanced isolation, operating temperature of -40℃ to +85℃, Input Under-voltage Protection, Output short circuit,
over-current, over–voltage protection.Railway vehicle electronic equipment widely used in 72V, 96V and 110V.
Selection Guide
④
Input Voltage (VDC)
②
Output
Efficiency
(%,Min./Typ.)
@ Full Load
Max. Capacitive
①
Certification
Part No.
⑤
Nominal
Output Voltage
(VDC)
Output Current
(mA)(Max./Min.)
③
Load(µF)
Max.
(Range)
URE1D12LD-20WR3
URE1D15LD-20WR3
URE1D24LD-20WR3
±12
±15
±24
±833/0
83/85
84/86
84/86
680
470
220
110
170
--
±667/0
(40-160)
±417/0
Note:
①Series with suffix “H” are heat sink mounting; series with suffix “A2S” are chassis mounting,with suffix “A4S” are DIN-Rail mounting, for example
URE1D12LD-20WHR3A2S is chassis mounting of with heat sink, URE1D12LD-20WR3A4S is DIN-Rail mounting of without heat sink; If the application has a higher
requirement for heat dissipation, you can choose modules with heat sink;
②A2S (wiring) and A4S (rail) Model due to input reverse polarity protection function, input voltage range the minimum value and starting voltage is higher than
1VDC DIP package;
③Absolute maximum rating without damage on the converter, but it isn't recommended;
④Efficiency is measured In nominal input voltage and rated output load;A2S (wiring) and A4S (rail) Model due to input reverse polarity protection, minimum
efficiency greater than Min.-2 is qualified.
⑤For the dual output modules, the capacitive loads of positive and negative outputs are the same.
Input Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Unit
mA
Input Current (full load / no-load) Nominal input voltage
--
--
212/3
25
--
217/8
--
Reflected Ripple Current
Surge Voltage (1sec. max.)
Starting Voltage
Shutdown Voltage
Starting Time
Nominal input voltage
-0.7
--
180
40
100% load
VDC
ms
--
33
10
28
--
--
Nominal input voltage & constant resistance load
--
Input Filter
Pi filter
Unavailable
Hot Plug
Ctrl suspended or connected to TTL high level
(3.5-12VDC)
Module switch on
Ctrl*
Module switch off
Ctrl pin connected to GND or low level (0-1.2VDC)
Input current when switched off
mA
--
2
7
Note: * the voltage of Ctrl pin is relative to input pin GND.
2017.11.23-A/0
Page 1 of 8