URB_MP-12W Series
12W, WIDE INPUT, ISOLATED & REGULATED
SINGLE OUTPUT DC-DC CONVERTER
multi-country patent protection RoHS
FEATURES
PRODUCT PROGRAM
Efficiency up to 88%
Input
Output
Part
Number
Efficiency
(%, Typ)
Wide (4:1) Input Range
12W Rated Power Output
1.5KVDC Input/Output Isolation
Operating Temperature: -40°C to+85°C
DIP24 Package
Industry Standard Pinout
Five-sided Metal Shielding Package
Over Voltage Protection
Output Short Circuit Protection
Remote ON/OFF
Voltage (VDC)
Current (mA)
Max Min
No-load Voltage
(typ, mA) (VDC)
Capacitance
(Max,uF)
Nominal Range Max**
URB2403MP-12W
URB2405MP-12W *
URB2412MP-12W *
URB2415MP-12W *
URB4803MP-12W *
URB4805MP-12W *
URB4812MP-12W *
URB4815MP-12W *
55
55
25
25
20
20
10
10
3.3
5
3500
2400
1000
800
0
0
0
0
0
0
0
0
3000
2000
500
85
86
86
86
85
87
87
88
24
48
9-36
40
80
12
15
3.3
5
400
3500
2400
1000
800
3000
2000
500
18-75
12
15
400
*Designing.
**Input voltage can’t exceed this value, or will cause the permanent damage.
APPLICATIONS
INPUT SPECIFICATIONS
The URB_MP-12W Series are particularly
suited to data transfer equipments, battery
operated equipments, tele-communication
equipments, distributed power system, mix
analog/digital system, remote control
system, industrial robot system and other
wide input voltage application fields.
Item
Test Conditions
Min
Typ
500
8.8
Max
Units
mS
Start-up time
Input voltage range refer to output load
DC-DC Module ON
Nominal input(24V)
9
8.5
17.5
17
DC-DC Module OFF
8.3
Under Voltage protection
VDC
DC-DC Module ON
Nominal input(48V)
17
DC-DC Module OFF
16.5
3
0
40
VDC
VDC
DC-DC Module ON
DC-DC Module OFF
CTRL
Or open circuit
1.2
OUTPUT SPECIFICATIONS
MODEL SELECTION
URB2403MP-12W
Item
Test Conditions
Min
350
Typ
Max
12
Units
W
Output Power
Ripple& Noise
Switching Frequency
25°C environment temperature
20MHz Bandwidth
Rated Power
Package Style
Output Voltage
Input Voltage
85
mV
KHz
From 10% to 100% load
400
±1
450
±3
Product Series
Output Voltage Accuracy Input voltage range refer to output load
%
Voltage regulation
Load Regulation
Input voltage from low to high
±0.2
±0.5
0.02
4.3
6
±0.5
±1.5
Nominal input,10% to 100% load
Temperature Drift(Vout) 25°C environment temperature
3.3
%/°C
MORNSUN Science & Technology co.,Ltd.
Address: 2th floor 6th building, Huangzhou
Industrial District, Guangzhou, China
Tel: 86-20-38601850
5
Output voltage
(VDC)
Over voltage protection
VDC
12
15
13
16
Fax: 86-20-38601272
Http://www.mornsun-power.com
Short circuit protection
Continuous, automatic recovery
MORNSUN reserves the copyright
Specifications subject to change without notice.
URB_MP-12W
A/0-2008
Page 1 of 2