DC/DC Converter
URB1D_LD-15W & URB1D_LD-20W Series
15W&20W,Ultra wide input isolated & regulated
DC/DC converter
FEATURES
Wide range of input voltage (4:1)
Efficiency up to 89%
Isolation voltage :1.5K VDC
Operating temperature range: -40℃ to +85℃
Output over current protection, output over
voltage
protection,
output
short
circuit
protection(automatic recovery)
Six-sided metal shielding package
International standard pin-out
A2S (wring mounting) and A4S (35mm rail
mounting) products featuring anti-reverse
connection for inpu
Meet EN60950
Patent Protection RoHS
URB1D_LD-15W & URB1D_LD-20W series Wide input voltage range is 40-160VDC. It is suitable for 72 V, 96 V, 110 V standard input of the bus
voltage,single output and 1500VDC isolation,over current, over voltage and short-circuit protection.It offers good EMC performance,meet
EN60950 standards.All models are particularly suited to railway etc.
Selection Guide
Input Voltage (VDC)
Output
Output Current
Efficiency
③
(%,Min/Typ.)
@ Full Load
Max. Capacitive
Load(µF)
①
Part No.
Certification
Nominal
(Range)
Output Voltage
(VDC)
②
Max.
(mA)(Max./Min.)
4000/200
3000/150
1250/63
URB1D03LD-15W
URB1D05LD-15W
URB1D12LD-15W
URB1D15LD-15W
URB1D24LD-15W
URB1D05LD-20W
URB1D12LD-20W
URB1D15LD-20W
URB1D24LD-20W
3.3
5
85/87
4020
4020
1600
1000
470
87/89
12
15
24
5
86/88
1000/50
86/88
110
176
CE
625/32
86/88
(40-160)
4000/200
1667/83
87/89
4020
1600
1000
470
12
15
24
86/88
1333/67
86/88
833/42
86/88
Note:
①Series with suffix “H” are heat sink mounting; series with suffix “A2S” are chassis mounting,with suffix “A4S” are DIN-Rail mounting, for example
URB1D05LD-20WHA2S is chassis mounting of with heat sink,URB1D05LD-20WA4S is DIN-Rail mounting of without heat sink;If the application has a higher
requirement for heat dissipation, you can choose modules with heat sink;
②Absolute maximum rating without damage on the converter, but it isn't recommended;
③The efficiency of A2S (wiring type) and A4S (rail type) products is 2% lower than the above-mentioned value due to the reverse connection protection for
input;
Input Specifications
Item
Operating Conditions
URB1D_LD-15W Series
URB1D_LD-20W Series
Min.
--
Typ.
Max.
Unit
mA
153/15
204/15
25
159/20
212/20
--
Input Current (full load / no-load)
--
Reflected Ripple Current
Input impulse Voltage (1sec. max.)
Starting Voltage
--
-0.7
--
--
--
200
39.8
--
VDC
ms
100% load
Start-up Time
Nominal input& constant resistance load
--
10
Input Filter
Pi filter
2015.08.27-A/3
Page 1 of 8