End of Life - Not Recommended for New Designs
MicroPAC
S
®
C
NRTL US
C
US
AC-DC Power Supply
Features
• High efficiency up to 92%
• Output series capability
• Output current sharing
• Small Size
• High power density (25 W/In3)
• MicroPAC to MicroPAC Current sharing
• Optional power shed capability
• Over temperature warning
• Up to 1300 W (Configuration dependent)
• Low power standby mode (Green mode)
• Universal Input ((47-63 Hz) (400 Hz) (85 to 264 Vac)
• DC Input (120 – 300 Vdc)
• Over temperature shut down
• Intelligent fan control
• Up to 4 isolated outputs
• Field replaceable fan
• Standard 12 V, 14 V, 24 V, 28 V, 36 V & 48 V output
• Aux isolated 5 V @ 500 mA bias standby supply
• Output parallel capability
• Individual output enable / disable
• All output enables / disable capability
• TTL control signals
• All customer interface signals are isolated
• Visual LED display panel
• External Serial interface and GUI (Part Number CI-01)
Product Description
The MicroPAC is the first Westcor product to utilize Vicor’s VI Chip technology. The power supply uses
BCM modules to provide up to 4 isolated semi regulated output voltages of 12, 14, 24, 28, 36 and 48 Vdc and
up to 1300 W of continuous power in a very small highly efficient package. The isolated outputs may be placed in parallel/series
configurations and for applications requiring higher power levels MicroPAC power supplies can be configured in arrays up to
several KW. Safety agency approvals limit the configured output voltages to 60Vdc. Configurations and applications where output
voltages are greater than 60Vdc are non-SELV.
This factory configurable rugged power supply supports a wide range of customer power requirements and is especially suited for
distributed power architectures. The design offers a small flexible cost effective solution for applications requiring Power Factor
Correction, high efficiency and power density even in environmentally challenging conditions.
Part Numbering
U P
a
–
b
b
b
b
c
d
e
Output Configuration
Fill in character from chart below for each output
RoHS
Compliant
Interface Customer Option
Cooling
MicroPAC
Constant
Non-Safety Related
F = Fan
L = -40C Fan
M = Confrontal Coat
S = Standard (TTL levels)
G = RoHS
N = Non-RoHS
b = Vout
Watts
300
b = Vout Watts
Signaling and Control
A
B
C
D
E
12
12
12
12
24
24
14
14
14
14
G
H
I
48
48
48
48
325
650
Number of
outputs,
1 to 4
600
900
975
1200
600
J
1300
K
T
36
28
900
600
F
1200
300
Examples:
28
[a]
[b]
1200
[a]
P
U
M
Z
UP1-FZZZ-FSG
Denotes a single output of 24 V 1200 W
Q
R
S
600
with a standard fan, standard TTL signaling and control,
RoHS compliant
[b]
900
1200
UP4-AAAA-LSN
Denotes 4 output unit, each output is 12 V 300 W.
The fan is a -40°C capable unit, standard TTL signaling,
and the unit is non-RoHS
[a] M defines a slot with an air block filler, no BCM board
[b] Z indicates the slot is populated with a BCM board that is
connected in series or parallel with the adjacent slot
MicroPAC
Page 1 of 5
Rev 1.2
vicorpower.com
800 735.6200